ACV Thermostat mit manuellem oder automatischem Rücksetzer und Kapillarrohr 54764006
SKU 54764006
Marke ACV
Marke ACV
Wichtige technische Daten
| Reset-Typ | manual or automatic |
|---|---|
| Kontaktkonfiguration | normally closed or normally open |
| Elektrische Nennleistung | must match original |
| Leuchtmittelform | immersion or clamp-on |
52,14EUR
auf Lager · 2zzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung · Versandkosten werden an der Kasse berechnet
- Lieferung in 97 Länder
- Original-Ersatzteil vom Hersteller
- Versand innerhalb von 24 h bei Lagerware
Beschreibung
ACV Thermostat with manual or automatic reset, featuring a capillary bulb for remote temperature sensing. It is designed for use in HeatMaster 45 and HeatMaster 60 boilers. The thermostat acts as a high-limit or safety device, interrupting the control circuit when the sensed temperature exceeds the setpoint. The reset function allows rearming after the temperature drops. The bulb form can be immersion or clamp-on, and the contact configuration is normally closed or normally open, with electrical rating matching the original.
Weitere Angaben
| Action type | acts directly on burner control or safety circuit |
|---|---|
| Boiler overheat protection | disconnects boiler in case of overheating and requires user action to restore function |
| Design features | capillary bulb for remote temperature sensing |
| Features | improved operational safety, oem compatibility, reliable response to overheating |
| Operation principle | when sensed temperature exceeds setpoint, interrupts control circuit; reset allows rearming when temperature drops |
| Switching mechanism mounting | mounted on a panel or junction box |
| Switching point drift | boiler modulates incorrectly or fails to cut off |
| Switching temperature printing | often printed on thermostat body or in manufacturer's data |
Auswahl und Einbau
When selecting a replacement thermostat of this type, verify the switching temperature (setpoint), reset type (manual or automatic), capillary tube length, and bulb form (immersion or clamp-on). The electrical rating and contact configuration (normally closed or normally open) must match the original. Ensure the capillary length reaches the mounting point without sharp bends, and that the reset mechanism is accessible. For clamp-on bulbs, secure correctly and apply heat-conductive paste for accurate response.
Anzeichen für einen Defekt
Typical failures include drifting switching point, causing the boiler to modulate incorrectly or fail to cut off. A broken capillary tube or poor thermal contact between the bulb and pipe can also occur. Check for these issues if the boiler overheat protection is not functioning properly.
Passend für Geräte
HeatMaster 45 HeatMaster 60Heatmaster 45Heatmaster 60
Alle technischen Daten
| Reset-Typ | manual or automatic |
|---|---|
| Kontaktkonfiguration | normally closed or normally open |
| Elektrische Nennleistung | must match original |
| Leuchtmittelform | immersion or clamp-on |
Teilenummern
| SKU | 54764006 |
|---|---|
| Additional article | 129.805.009 |
Ähnliche Teile
62,04 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
22,92 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
22,37 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
42,66 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
26,52 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
35,16 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung
47,58 EURzzgl. MwSt. · Einfuhrumsatzsteuer und Zölle bei Lieferung