ACV Thermostat with manual or automatic reset, featuring a capillary 54764006

SKU 54764006 Brand ACV
ACV logo — ACV spare parts for burners and boilers Brand ACV
Buy ACV Thermostat with manual or automatic reset, featuring a capillary 54764006

Key specifications

Reset typemanual or automatic
Contact configurationnormally closed or normally open
Electrical ratingmust match original
Bulb formimmersion or clamp-on
all specifications (4) ↓

52.14EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

ACV Thermostat with manual or automatic reset, featuring a capillary bulb for remote temperature sensing. It is designed for use in HeatMaster 45 and HeatMaster 60 boilers. The thermostat acts as a high-limit or safety device, interrupting the control circuit when the sensed temperature exceeds the setpoint. The reset function allows rearming after the temperature drops. The bulb form can be immersion or clamp-on, and the contact configuration is normally closed or normally open, with electrical rating matching the original.

Further details

Action typeacts directly on burner control or safety circuit
Boiler overheat protectiondisconnects boiler in case of overheating and requires user action to restore function
Design featurescapillary bulb for remote temperature sensing
Featuresimproved operational safety, oem compatibility, reliable response to overheating
Operation principlewhen sensed temperature exceeds setpoint, interrupts control circuit; reset allows rearming when temperature drops
Switching mechanism mountingmounted on a panel or junction box
Switching point driftboiler modulates incorrectly or fails to cut off
Switching temperature printingoften printed on thermostat body or in manufacturer's data

Choosing and fitting

When selecting a replacement thermostat of this type, verify the switching temperature (setpoint), reset type (manual or automatic), capillary tube length, and bulb form (immersion or clamp-on). The electrical rating and contact configuration (normally closed or normally open) must match the original. Ensure the capillary length reaches the mounting point without sharp bends, and that the reset mechanism is accessible. For clamp-on bulbs, secure correctly and apply heat-conductive paste for accurate response.

Signs of failure

Typical failures include drifting switching point, causing the boiler to modulate incorrectly or fail to cut off. A broken capillary tube or poor thermal contact between the bulb and pipe can also occur. Check for these issues if the boiler overheat protection is not functioning properly.

Fits equipment

HeatMaster 45 HeatMaster 60Heatmaster 45Heatmaster 60

All specifications

Reset typemanual or automatic
Contact configurationnormally closed or normally open
Electrical ratingmust match original
Bulb formimmersion or clamp-on

Part numbers

SKU54764006
Additional article129.805.009

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
52.14 EUR 1