10,14 EURHT · TVA à l'importation et droits de douane à la livraison
Caractéristiques principales
| Courant nominal | 12.5 a |
|---|---|
| Taille du fusible | 6.3 mm |
| Vitesse du fusible | slow-blow (time-lag) |
| Chaudières d'application | ACV boilers |
9,54EUR
en stock · 1HT · TVA à l'importation et droits de douane à la livraison · frais de livraison calculés lors du paiement
- Livraison dans 97 pays
- Pièce d'origine du fabricant
- Expédition sous 24 h pour les articles en stock
Description
The ACV Slow-blow fuse 5476C011 is a 12.5 A, 6.3 mm fuse with a slow-blow (time-lag) characteristic, designed for use in ACV boilers. It fits models including the HeatMaster 45 TC Smart ME Prestige Solo MK2 and HeatMaster 45 TC. This fuse protects control boards, ignition transformers, and low-voltage circuits from overcurrent and short circuits. Its slow-blow action tolerates brief inrush currents during start-up, preventing nuisance trips.
Informations complémentaires
| Advantages | fast response to voltage surges, reliable component protection, factory-approved original part |
|---|---|
| Protection function | protects control board, ignition transformer, and low-voltage circuits against overcurrent and short circuits |
| Used in models | Heatmaster 45 TC Smart Me Prestige Solo MK2 |
Choix et montage
When selecting a fuse of this type, match the physical dimensions (e.g., 6.3 x 32 mm), current rating, and speed (slow-blow) to the original. Verify the voltage rating on the fuse body is at least the circuit voltage. Never use a higher current rating or faster speed, as this compromises protection. Always investigate the cause of a blown fuse before replacement.
Signes de défaillance
A blown fuse of this kind typically results from a shorted component or failing transformer, causing the boiler to lose power to protected circuits. Symptoms include the boiler failing to start, control board not powering up, or ignition transformer not operating. Check the fuse continuity and inspect for visible damage or discoloration.
Compatible avec
HeatMaster 45 TC
Toutes les caractéristiques
| Courant nominal | 12.5 a |
|---|---|
| Taille du fusible | 6.3 mm |
| Vitesse du fusible | slow-blow (time-lag) |
| Chaudières d'application | ACV boilers |
Références
| SKU | 5476C011 |
|---|---|
| Additional article | 129.595.001 |
Pièces similaires
8,34 EURHT · TVA à l'importation et droits de douane à la livraison
5,82 EURHT · TVA à l'importation et droits de douane à la livraison
60,00 EURHT · TVA à l'importation et droits de douane à la livraison
7,44 EURHT · TVA à l'importation et droits de douane à la livraison
184,02 EURHT · TVA à l'importation et droits de douane à la livraison
347,82 EURHT · TVA à l'importation et droits de douane à la livraison
29,40 EURHT · TVA à l'importation et droits de douane à la livraison




































































