Key specifications

Supply voltage230 V
Safety time10 s
Flame detector typeionisation
Protection class (IP)IP00
Body materialimpact-resistant, self-extinguishing plastic
CertificationEN 298:2003
FuelGas
Firing stagesprogressive (modulating)
Applicationheating and heat generation systems
Safety standardEN 298:2003
Air supplywith or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual reset lockout
Application typeatmospheric gas burners
Installation positionany
Operating principlemicroprocessor-based controller
Flame monitoringionisation
Pre-purge time1.5 s
all specifications (21) ↓
130.80 EUR

Lowest price in the 30 days before the price drop

119.88EUR

in stock · 1

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Control box 20080005 is a microprocessor-based controller for atmospheric gas burners in heating and heat generation systems. It operates with a supply voltage of 230 V and features a safety time of 10 seconds and a pre-purge time of 1.5 seconds. Flame detection is via ionisation, with a flame loss reaction time of less than 1 second. The device supports progressive (modulating) burner stages and is certified to EN 298:2003. It is designed for intermittent operation and has a service life of 250,000 cycles under maximum load.

Choosing and fitting

Control boxes of this type are selected by matching the supply voltage, safety time, pre-purge time, and flame detection method to the burner's requirements. They are typically mounted on a DIN rail or by screws, and installation position is flexible. Ensure the control box is compatible with the burner's fuel type and stage control (e.g., progressive). The flame detector type (ionisation) must correspond to the burner's electrode configuration.

Signs of failure

Common failures include lockout due to flame loss, which triggers a manual reset. Symptoms may include the burner failing to start or shutting down unexpectedly. Check the ionisation electrode for contamination or wear, and verify wiring integrity and gas supply. A red LED indicates a safety lockout, requiring manual reset after resolving the fault.

All specifications

Supply voltage230 V
Safety time10 s
Flame detector typeionisation
Protection class (IP)IP00
Body materialimpact-resistant, self-extinguishing plastic
CertificationEN 298:2003
FuelGas
Firing stagesprogressive (modulating)
Applicationheating and heat generation systems
Safety standardEN 298:2003
Air supplywith or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual reset lockout
Application typeatmospheric gas burners
Installation positionany
Operating principlemicroprocessor-based controller
Flame monitoringionisation
Pre-purge time1.5 s

Part numbers

SKU20080005
Additional article246.124.030

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
119.88 EUR 130.80 EUR 1