SKU 37100252 Model CM11F Brand Brahma
Brahma logo — Brahma spare parts for burners and boilers Brand Brahma
Buy Brahma Microprocessor-based controller CM11F 37100252

Key specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeionisation
CertificationEN 298:1993/2003, CE
FuelGas
Firing stagestwo-stage
Safety standardEN 298
Air supplyatmospheric, with or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual lockout reset
Operating principlemicroprocessor-based
External fuse3.15 A
Flame monitoringionisation
Operating voltage220-240 V AC, 50/60 Hz
Microprocessor-basedyes
EN 298 complianceyes
all specifications (19) ↓

129.84EUR

in stock · 1

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma CM11F (SKU 37100252) is a microprocessor-based controller for automatic ignition control, flame monitoring, and safe operation of two-stage atmospheric gas burners. It operates at 220–240 V AC, 50/60 Hz, with a safety time of 10 seconds and flame detection via ionisation. The unit supports intermittent (cyclic) operation and is certified to EN 298:1993/2003 and CE. It includes a manual lockout reset and an external fuse rating of 3.15 A. The controller has a service life of 250,000 cycles under maximum load.

Choosing and fitting

When selecting a replacement control box of this type, verify the supply voltage, safety time, and flame detection method (ionisation) match the burner's requirements. Ensure the unit is compatible with two-stage burners and the operating mode (intermittent) aligns with the application. Check the mounting form and connection base compatibility, as these may vary. Compare the pre-purge and waiting times marked on the old unit with the new one, as these can differ between versions.

Signs of failure

Typical failures include loss of flame detection, leading to a safety lockout that requires manual reset. The burner may fail to ignite or shut down unexpectedly. Check the ionisation electrode for contamination or incorrect positioning, and verify the external fuse is intact. If the unit does not reset, the internal components may be faulty, requiring replacement.

All specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeionisation
CertificationEN 298:1993/2003, CE
FuelGas
Firing stagestwo-stage
Safety standardEN 298
Air supplyatmospheric, with or without fan
Service life under maximum load250000
Cycle typeintermittent
Flame detection methods supportedionisation
Flame loss reaction timeless than 1 second
Safety featuremanual lockout reset
Operating principlemicroprocessor-based
External fuse3.15 A
Flame monitoringionisation
Operating voltage220-240 V AC, 50/60 Hz
Microprocessor-basedyes
EN 298 complianceyes

Part numbers

SKU37100252
Additional article246.124.136
ModelCM11F

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
129.84 EUR 1