Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | self-extinguishing plastic |
| Country of origin | Italy |
| Certification | EN 298:1993/2003, CE |
| Fuel | Gas |
| Firing stages | two-stage |
| Safety standard | EN 298 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Installation position | any |
| Operating principle | microprocessor-based controller |
| Flame monitoring | ionisation flame control |
| Operating voltage | 220-240 V AC |
| Housing type | compact impact-resistant housing |
| Microprocessor-based | yes |
| Mounting position | any |
| EN 298 compliance | yes |
| Storage conditions | -20–70 °C |
| Pre-purge time | 1.5 s |
Lowest price in the 30 days before the price drop
142.38EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Control box CM12F 37103253 is a microprocessor-based controller designed for automatic ignition control, flame monitoring, and safe operation of two-stage atmospheric gas burners in intermittent mode. It operates at 220–240 V AC and uses ionisation flame detection with a reaction time of less than 1 second. The unit features a manual lockout reset, is housed in self-extinguishing plastic with IP00 protection, and complies with EN 298:1993/2003 and CE standards. It is suitable for gas burners and has a service life of 250,000 cycles under maximum load.
Further details
| Application Type | automatic ignition control, flame monitoring and safe operation |
|---|
Choosing and fitting
Parts of this type are selected by matching the supply voltage, flame detection method, and burner stage configuration. Installation must consider the mounting position (any) and the need for a protective enclosure due to IP00 rating. Before ordering, verify the pre-purge time and safety time specifications on the housing label, as these can vary. The unit can be mounted on a DIN rail or by screws.
Signs of failure
Common failures include lockout due to flame loss or ignition failure, often caused by a dirty or worn ionisation electrode. The equipment may fail to start or shut down unexpectedly, requiring manual reset after addressing the root cause. Check the ionisation electrode gap and insulation, and ensure the gas supply and ignition components are functioning.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | self-extinguishing plastic |
| Country of origin | Italy |
| Certification | EN 298:1993/2003, CE |
| Fuel | Gas |
| Firing stages | two-stage |
| Safety standard | EN 298 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Installation position | any |
| Operating principle | microprocessor-based controller |
| Flame monitoring | ionisation flame control |
| Operating voltage | 220-240 V AC |
| Housing type | compact impact-resistant housing |
| Microprocessor-based | yes |
| Mounting position | any |
| EN 298 compliance | yes |
| Storage conditions | -20–70 °C |
| Pre-purge time | 1.5 s |