Key specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Country of origin | Italy |
| Certification | EN 298:2003 |
| Fuel | Gas |
| Firing stages | progressive (modulating) |
| Application | heating equipment |
| Safety standard | EN 298:2003 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Dimensions | 116 x 96 x 36 mm |
| Ambient temperature | -20–60 °C |
| Weight | 170 g |
| Ignition type | built-in high-voltage ignition transformer |
| Operating voltage | 230 V AC |
| Microprocessor-based | yes |
| Pre-purge time | 30 s |
| Net weight | 0.17 kg |
134.82EUR
in stock · 2excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma CM31 (SKU 30082315) is a microprocessor-based burner management unit designed for progressive (modulating) atmospheric gas burners. It operates at 230 V AC and includes a built-in high-voltage ignition transformer. The unit features a pre-purge time of 30 seconds, a safety time of 5 seconds, and uses ionisation flame detection with a reaction time of less than 1 second on flame loss. It has a manual lockout reset and is certified to EN 298:2003. The device measures 116 x 96 x 36 mm, weighs 170 g, and has an ambient temperature range of -20 to 60 °C.
Choosing and fitting
Parts of this type are selected by matching the supply voltage, flame detection method, and safety time to the burner's requirements. The unit must be installed in a protective control cabinet due to its IP00 protection class. Ensure the mounting dimensions and connection diagram align with the existing wiring. The base is typically purchased separately.
Signs of failure
Common failures include lockout due to ignition failure or flame loss, often caused by a faulty ionisation probe or contaminated flame sensor. The equipment may shut down and require manual reset. Check the flame detection circuit and ignition transformer for proper operation.
All specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Country of origin | Italy |
| Certification | EN 298:2003 |
| Fuel | Gas |
| Firing stages | progressive (modulating) |
| Application | heating equipment |
| Safety standard | EN 298:2003 |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | less than 1 second |
| Safety feature | manual lockout reset |
| Dimensions | 116 x 96 x 36 mm |
| Ambient temperature | -20–60 °C |
| Weight | 170 g |
| Ignition type | built-in high-voltage ignition transformer |
| Operating voltage | 230 V AC |
| Microprocessor-based | yes |
| Pre-purge time | 30 s |
| Net weight | 0.17 kg |
Part numbers
| SKU | 30082315 |
|---|---|
| Additional article | 246.124.051 |
| Model | CM31 |
Similar parts