Key specifications
| Supply voltage | 230–230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | non-flammable plastic |
| Certification | CE |
| Fuel | Gas |
| Firing stages | progressive (modulating) |
| Connection type | microflat-type connection base |
| Safety standard | EN298:1993 and EN298:2003 |
| Air supply | with or without fan |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | <1 s |
| Safety feature | non-volatile lockout with manual reset |
| Installation position | any |
| Operating principle | microprocessor controller |
| Flame monitoring | ionisation |
| Pre-purge time | 1.5 s |
135.42EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Control box CM31U 37056010 is a microprocessor-based controller for atmospheric gas burners of progressive (modulating) type, operating with or without a fan. It features a non-volatile lockout with manual reset, ionisation flame monitoring with a reaction time of less than 1 second, and a safety time of 10 seconds. The device has a pre-purge time of 1.5 seconds, operates at 230 V AC, and is certified to EN298:1993 and EN298:2003 with CE marking. It is designed for intermittent operation and has a service life of 250,000 cycles under maximum load. The control box is housed in non-flammable plastic with IP00 protection and connects via a microflat-type base.
Choosing and fitting
Parts of this type are selected by matching the supply voltage, safety time, pre-purge time, and flame detection method to the burner's specifications. The connection type must be compatible with the existing base, and the control box must be installed in a protective enclosure with at least IP20 rating due to its IP00 protection. Ensure the mounting position is any, but the unit must be placed in a dry, ventilated area. Before ordering, verify the article number and model against the burner's documentation.
Signs of failure
When such controllers fail, the burner may lock out without restarting, indicated by a red LED. Common causes include a faulty flame sensor, incorrect wiring, or voltage surges. Check the ionisation electrode for contamination or wear, and verify the gas supply and electrical connections. If the unit locks out, press the manual reset button after resolving the issue.
All specifications
| Supply voltage | 230–230 V |
|---|---|
| Safety time | 10 s |
| Flame detector type | ionisation |
| Protection class (IP) | IP00 |
| Body material | non-flammable plastic |
| Certification | CE |
| Fuel | Gas |
| Firing stages | progressive (modulating) |
| Connection type | microflat-type connection base |
| Safety standard | EN298:1993 and EN298:2003 |
| Air supply | with or without fan |
| Service life under maximum load | 250000 |
| Cycle type | intermittent |
| Flame detection methods supported | ionisation |
| Flame loss reaction time | <1 s |
| Safety feature | non-volatile lockout with manual reset |
| Installation position | any |
| Operating principle | microprocessor controller |
| Flame monitoring | ionisation |
| Pre-purge time | 1.5 s |
Part numbers
| SKU | 37056010 |
|---|---|
| Additional article | 246.124.067 |
| Model | CM31U |
Similar parts
297.00 EURexcl. VAT · import VAT and duties on delivery