Key specifications
| Flame detector type | ionisation |
|---|---|
| Firing stages | two-stage |
| Fuel | gas and oil |
| Cycle type | intermittent (cyclic) mode |
| Flame loss reaction time | less than 1 second |
| Independent safety contacts | 2 contacts |
| Microprocessor-based | yes |
| Device type | flame safeguard or burner control |
| Driven components | fan, ignition transformer, fuel valve |
| Air pressure switch verification | yes |
| Lockout on flame detection failure | yes |
| Modulation actuator drive | may interact with modulating actuators |
195.84EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Microprocessor-based flame safeguard controller for two-stage gas and oil burners operating in intermittent (cyclic) mode. It uses ionisation flame detection, with a flame-loss reaction time of less than 1 second, and provides two independent safety contacts. The controller verifies the air pressure switch, then drives the fan, ignition transformer, and fuel valve; it may interact with modulating actuators. In the event of flame failure, it locks out.
Further details
| Application | boiler, climate and thermal, water heating and process equipment |
|---|---|
| Application Type | automating ignition processes, flame monitoring and safe burner shutdown |
Choosing and fitting
Parts of this type are selected by exact series and type designation, supply voltage, safety times, pre-purge times, and the flame detection method. The base or plug pattern varies; a replacement must match the original pattern, and controls from different series of the same brand are not interchangeable. Before ordering, verify the existing unit's type designation, voltage, connector arrangement, and safety time. A mismatched safety time or flame detection method will cause incorrect operation or lockout.
All specifications
| Flame detector type | ionisation |
|---|---|
| Firing stages | two-stage |
| Fuel | gas and oil |
| Cycle type | intermittent (cyclic) mode |
| Flame loss reaction time | less than 1 second |
| Independent safety contacts | 2 contacts |
| Microprocessor-based | yes |
| Device type | flame safeguard or burner control |
| Driven components | fan, ignition transformer, fuel valve |
| Air pressure switch verification | yes |
| Lockout on flame detection failure | yes |
| Modulation actuator drive | may interact with modulating actuators |
Part numbers
| SKU | 37508000 |
|---|---|
| Additional article | 246.124.246 |
| Model | DMN11 |