SKU 37200835 Model VM45G Brand Brahma
Brahma logo — Brahma spare parts for burners and boilers Brand Brahma
Buy Brahma Control box VM45G 37200835

Key specifications

Supply voltage220–240 V
Safety time3 s
Flame detector typeionization electrode or UV photodiode
Protection class (IP)IP40
CertificationCE, EAC, FM
Fuelgas and fuel oil
Applicationindustrial and domestic heating systems
Air supplyforced draft
Service life under maximum load250000
Flame detection methods supportedionization, UV
Safety featurenon-volatile locking requiring manual reset
Base presentno
Pre-purge time5 s
Net weight0.25 kg
all specifications (14) ↓

309.02EUR

in stock · 3

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma VM45G control box (SKU 37200835) is a safety and control unit for gas and fuel oil burners with forced draft. It operates on a supply voltage of 220–240 V and features a safety time of 3 seconds and a pre-purge time of 5 seconds. Flame detection is supported via ionization electrode or UV photodiode. The device has a net weight of 0.25 kg, protection class IP40, and certifications CE, EAC, and FM. It includes a non-volatile locking safety feature requiring manual reset and is suitable for industrial and domestic heating systems.

Choosing and fitting

Control boxes of this type are selected by matching the supply voltage, safety time, pre-purge time, and flame detection method to the burner's specifications. Ensure the control box is compatible with the burner's fuel type (gas or oil) and air supply (forced draft). Mounting may require a base or direct panel installation; verify the physical dimensions and connection type. Compare the electrical ratings and certifications with the existing system requirements before installation.

Signs of failure

Common failures include the control box locking out without reset, which may be due to flame detection issues or voltage fluctuations. Symptoms include the burner failing to start, repeated lockouts, or the system not responding to reset attempts. Check the flame sensor, wiring connections, and supply voltage for proper operation.

All specifications

Supply voltage220–240 V
Safety time3 s
Flame detector typeionization electrode or UV photodiode
Protection class (IP)IP40
CertificationCE, EAC, FM
Fuelgas and fuel oil
Applicationindustrial and domestic heating systems
Air supplyforced draft
Service life under maximum load250000
Flame detection methods supportedionization, UV
Safety featurenon-volatile locking requiring manual reset
Base presentno
Pre-purge time5 s
Net weight0.25 kg

Part numbers

SKU37200835
Additional article246.124.123
ModelVM45G

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
309.02 EUR 1