Brahma Electronic control board (PCB) GP 458.1N001 16020250

SKU 16020250 Model GP 458.1N001 Brand Brahma
Brahma logo — Brahma spare parts for burners and boilers Brand Brahma
Buy Brahma Electronic control board (PCB) GP 458.1N001 16020250

Key specifications

Flame detector typeionisation, uv, or ir
Flame detection methodionisation, uv, or ir
Applicationmodern wall-hung boilers
Ignition systems supporteddrives the ignition transformer
Lockout on faultlockout on failure
all specifications (5) ↓

45.00EUR

in stock · 1

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma GP 458.1N001 is an electronic control board (PCB) for burner or boiler systems, functioning as a burner control (flame safeguard). It manages the ignition sequence and enforces safety times, including pre-purge, ignition, fuel admission, flame proving, and lockout on failure. The board reads signals from pressure switches and a flame detector (ionisation, UV, or IR) and drives the ignition transformer, gas valve, and fan. It is designed for modern wall-hung boilers and fits Master models B35CEL, B70CEL, B100CEL, and B150CEL. The type designation is 4110.142, with SKU 16020250.

Further details

Sensing Inputsreads signals from pressure switches and the flame detector

Choosing and fitting

When selecting a replacement control board of this type, the exact series and type designation must match the original, along with supply voltage, safety and pre-purge times, flame detection method, and base or plug pattern. Control boards are typically not interchangeable across series, even within the same brand; a mismatched safety time creates a safety issue. Verify that the replacement unit corresponds to the existing system's electrical and sequence parameters before installation.

Signs of failure

Items of this kind may fail due to electrical surges, component wear, or moisture, leading to erratic operation or complete lockout. Symptoms include failure to ignite, repeated lockouts, or the burner not responding to control signals. Check for visible damage on the board, loose connections, and verify that the flame detector and pressure switches are functioning correctly.

All specifications

Flame detector typeionisation, uv, or ir
Flame detection methodionisation, uv, or ir
Applicationmodern wall-hung boilers
Ignition systems supporteddrives the ignition transformer
Lockout on faultlockout on failure

Part numbers

SKU16020250
Additional article246.568.001
ModelGP 458.1N001
Type designation4110.142

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
45.00 EUR 1