49.44 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Compatible control type | Siemens burner controls |
|---|---|
| Device type | flame sensor |
| Fuel | oil and gas |
| Performance features | high sensitivity, stable operation, durability |
| Response characteristic | fast response to flame loss |
205.38EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Siemens RAR9 flame sensor is a device for oil and gas burners, compatible with Siemens burner controls. It detects the presence or absence of a flame and sends a corresponding signal to the control. The sensor provides fast response to flame loss and features high sensitivity, stable operation, and durability.
Further details
| Application | boiler plants, diesel and gas burners, as well as industrial heat engineering equipment |
|---|---|
| Electrical Connection | connected to the burner control or a dedicated flame amplifier |
| Maintenance Requirement | clean viewing window and check cable integrity |
| Output Signal | signal to the burner control when flame is present or absent |
| Purpose | monitor combustion process and send signal to burner control |
| Safety Function | emergency fuel shut-off in case of flame loss |
Choosing and fitting
Flame sensors of this type are selected by the detection principle required by the burner control (ionisation, UV, or IR) and by spectral range to match the fuel—luminous oil or blue gas. The sensor must be positioned with a direct line of sight to the flame, typically using a sleeve or bracket. The cable length, connector type, and mounting arrangement must match the original part, and the original manufacturer code or catalogue number should be used to verify compatibility with the burner control.
Signs of failure
Common failure modes include a contaminated window or lens that reduces sensitivity, an aged sensing cell that gives a weakened signal, or a damaged cable that causes intermittent or no signal. When the sensor fails, the burner control may lock out after ignition because it does not detect flame within the safety time, preventing unburned fuel accumulation. Regular cleaning of the viewing window and inspecting the cable for cuts or strain can help maintain proper operation.
All specifications
| Compatible control type | Siemens burner controls |
|---|---|
| Device type | flame sensor |
| Fuel | oil and gas |
| Performance features | high sensitivity, stable operation, durability |
| Response characteristic | fast response to flame loss |
Part numbers
| SKU | RAR9 |
|---|---|
| Additional article | 884.211.002 |
Similar parts
49.14 EURexcl. VAT · import VAT and duties on delivery
50.70 EURexcl. VAT · import VAT and duties on delivery
191.28 EURexcl. VAT · import VAT and duties on delivery
279.00 EURexcl. VAT · import VAT and duties on delivery
67.50 EURexcl. VAT · import VAT and duties on delivery
67.50 EURexcl. VAT · import VAT and duties on delivery
42.00 EURexcl. VAT · import VAT and duties on delivery




































































