882.00 EURexcl. VAT · import VAT and duties on delivery
Honeywell Gas solenoid valve VK4105G1070U
Brand Honeywell
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 1/2" external |
| Supply voltage | 230 V |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum working pressure | 60 bar |
| Maximum operating pressure | 60 mbar |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Output aperture diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN126 |
| Operating position | upright |
| Ambient pressure | 1013 mbar |
| Ignition electronics compatibility | S456..M |
| Built-in filter | fine-mesh filter |
| Optional output filter | additional output filter |
| Mounting feature | holes at the bottom |
| Design features | positive feedback system |
| Output pressure stability | stable output pressure |
| Gas type | heating, natural and liquefied |
| Included components | valve and ignition regulator |
| Valve type | solenoid valve |
| Operating principle | positive feedback system |
| Coil voltage type | AC |
| Electrical connection | connector or plug-in rectifier unit |
| Operating voltage | 24V |
| Housing type | standard housing |
| Control features | electric two-level regulator |
| Softlite technology | smooth ignition |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Pressure measuring points | top |
| Flanged connections | flanged connection |
| Flange collector required | flanged burner manifold |
| Frequency | 50 Hz |
| Flow capacity | 2.7 m³/h |
114.00EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VK4105G1070U is a gas solenoid valve designed for burner control and ignition systems, ensuring safe ignition and gas flow regulation for both pilot and main burners. It operates with a supply voltage of 230 V AC at 50 Hz, has a maximum inlet pressure of 60 mbar, and a flow capacity of 2.7 m³/h. The valve features a positive feedback system, pressure servo controller, and pressure relief valve, providing stable output pressure. It includes a built-in fine-mesh filter and is compatible with ignition electronics S456..M. The valve is suitable for heating, natural, and liquefied gases, and fits specific Ferroli boiler models.
Further details
| Back pressure | 1st valve: 50 mbar; 2nd valve |
|---|---|
| Capacity (by air) | 2.7 m3/h with a pressure drop of 3 mbar |
| Closing Variants | B + J, B + C, B + B |
| Gas connection | Inlet: 1/2" External outlet: side outlet with a diameter of 18.6 inches: - |
| Leakage requirements | According to EN126 |
| Pressure Measuring Fittings | silicone tubes with a diameter of 4 or 6 mm |
| Pressure valve | Top to measure inlet and outlet pressure |
| Rated power | 230 V AC; 50 Hz |
| Safety Feature | valve closes automatically when no power |
| Screen | On the input side |
Choosing and fitting
Parts of this type are selected by matching the connection thread, supply voltage, and maximum operating pressure to the existing system. The valve must be installed upright, and the inlet and outlet connections (e.g., 1/2" external thread) must align with the burner manifold. Ensure the flow capacity and pressure ratings meet the burner requirements. The valve may have flanged connections, requiring a flanged burner manifold for side outlets. Check the electrical connection type (connector or plug-in rectifier) and compatibility with the ignition electronics.
Signs of failure
Common failure modes include valve sticking open or closed, leading to gas flow issues or failure to ignite. Symptoms may include burner not starting, flame instability, or gas leakage. Check for proper electrical supply, coil continuity, and diaphragm integrity. Pressure fluctuations or inability to maintain output pressure may indicate servo controller or relief valve malfunction. Inspect the fine-mesh filter for clogging, which can restrict gas flow.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 1/2" external |
| Supply voltage | 230 V |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum working pressure | 60 bar |
| Maximum operating pressure | 60 mbar |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Output aperture diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN126 |
| Operating position | upright |
| Ambient pressure | 1013 mbar |
| Ignition electronics compatibility | S456..M |
| Built-in filter | fine-mesh filter |
| Optional output filter | additional output filter |
| Mounting feature | holes at the bottom |
| Design features | positive feedback system |
| Output pressure stability | stable output pressure |
| Gas type | heating, natural and liquefied |
| Included components | valve and ignition regulator |
| Valve type | solenoid valve |
| Operating principle | positive feedback system |
| Coil voltage type | AC |
| Electrical connection | connector or plug-in rectifier unit |
| Operating voltage | 24V |
| Housing type | standard housing |
| Control features | electric two-level regulator |
| Softlite technology | smooth ignition |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Pressure measuring points | top |
| Flanged connections | flanged connection |
| Flange collector required | flanged burner manifold |
| Frequency | 50 Hz |
| Flow capacity | 2.7 m³/h |
Part numbers
| SKU | VK4105G1070U |
|---|---|
| Additional article | 534.331.089 |
| Model | VK4105G1070 |
Similar parts
196.50 EURexcl. VAT · import VAT and duties on delivery