Kromschroder Solenoid gas valve VG8R05Q6 85231050

SKU 85231050 Model VG8R05Q6 Brand Kromschroder
Kromschroder logo — Kromschroder spare parts for burners and boilers Brand Kromschroder
Buy Kromschroder Solenoid gas valve VG8R05Q6 85231050

Key specifications

Body materialaluminum
Protection class (IP)IP54 / IP65
Connection typethreaded
Safety standardEN 161
Valve typesolenoid gas valve
Operating principlenormally closed, opens when energized
Operating temperature-20–60 °C
Normally closedyes
CertificationEN 161
Coil voltage120 V
Setting range0–500 mbar
Maximum pressure0.5 bar
Installationeasy installation and connection
SizeDN 8
Thread typeRp internal thread
ComplianceEN 161
Functiongas shut-off
Voltage typeAC
Default statenormally closed
Safety featureshigh safety
all specifications (20) ↓

249.60EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Kromschroder Solenoid gas valve VG8R05Q6 (SKU 85231050) is a compact, normally closed solenoid valve designed for automatic gas shut-off in pilot lines and small burners. It operates on 120 V AC and features a DN 8 connection with Rp internal thread. The valve body is made of aluminum, with a protection class of IP54/IP65 and a pressure range of 0–500 mbar. It complies with EN 161 and operates within a temperature range of -20 to 60 °C.

Further details

Applicationpilot gas lines, bypass and auxiliary lines, small gas burners and igniters
Gas Typesnatural gas, LPG, town gas, air

Choosing and fitting

Parts of this type are selected by brand and series, connection size (Rp 1/2" to 2" or flanged), coil voltage (230 V or 24 V AC/DC), and function—single or double solenoid, slow opening, servo-regulated, or multiblock with filter and regulator. When installing, ensure the coil voltage matches the control system, the thread type and size fit the existing piping, and the pressure rating is suitable for the application. The valve opens when energized and closes when de-energized, so wiring must be correct for the intended fail-safe operation.

Signs of failure

Typical failures include coil burnout, leaking seat, drifting outlet pressure, and seized servo regulator. When the coil fails, the valve may not open, preventing gas flow and causing the burner to fail to ignite. A leaking seat can cause gas to pass when the valve is closed, leading to unsafe conditions. Check the coil resistance and voltage supply, inspect the valve seat for debris or wear, and verify the outlet pressure against the setpoint.

All specifications

Body materialaluminum
Protection class (IP)IP54 / IP65
Connection typethreaded
Safety standardEN 161
Valve typesolenoid gas valve
Operating principlenormally closed, opens when energized
Operating temperature-20–60 °C
Normally closedyes
CertificationEN 161
Coil voltage120 V
Setting range0–500 mbar
Maximum pressure0.5 bar
Installationeasy installation and connection
SizeDN 8
Thread typeRp internal thread
ComplianceEN 161
Functiongas shut-off
Voltage typeAC
Default statenormally closed
Safety featureshigh safety

Part numbers

SKU85231050
Additional article624.337.186
ModelVG8R05Q6

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
249.60 EUR 1