Danfoss High-voltage ignition transformer EBI4 CM S 052F4047
Brand Danfoss
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Ignition current | 30 mA |
| Current | 0.25 A |
| Manufacturer code | 052F4047 |
| Ignition cable insulation | silicone-insulated |
| Cable condition check | check before replacing transformer |
| Secondary current | 30 mA |
| Frequency | 50–60 Hz |
72.00EUR
in stock · 5excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Danfoss EBI4 CM S high-voltage ignition transformer, SKU 052F4047, operates at 220–240 V supply voltage and 50–60 Hz frequency. It provides a secondary current of 30 mA and draws a primary current of 0.25 A. This transformer is used in burners to step up mains voltage to produce a spark for igniting the fuel-air mixture during the ignition phase. The ignition cables are silicone-insulated to withstand high voltage and heat.
Further details
| Application | for burners and industrial heating systems |
|---|---|
| Energization | energised only during the ignition phase |
| Replacement verification | verify primary voltage and secondary output |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify the primary voltage (typically 230 V, but 110 V and 24 V versions exist) and secondary output (voltage and current) against the burner control requirements and electrode gap specifications. Parts are chosen by secondary voltage and current, primary voltage, duty cycle, mounting arrangement, terminal type, and cable connector pattern. Before ordering, compare these specifications with the existing unit and ensure the mounting form matches.
Signs of failure
Common failure modes include internal short circuits or open windings, leading to no spark or weak spark. A hardened or cracked ignition cable can leak the spark to earth, mimicking a faulty transformer. Check the cable condition before replacing the transformer itself. If the burner fails to ignite or has intermittent ignition, inspect the transformer and cables for damage.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Ignition current | 30 mA |
| Current | 0.25 A |
| Manufacturer code | 052F4047 |
| Ignition cable insulation | silicone-insulated |
| Cable condition check | check before replacing transformer |
| Secondary current | 30 mA |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 052F4047 |
|---|---|
| Additional article | 327.820.001 |
| Model | EBI4 CM S |
Similar parts
33.00 EURexcl. VAT · import VAT and duties on delivery
244.62 EURexcl. VAT · import VAT and duties on delivery




































































