378.00 EURexcl. VAT · import VAT and duties on delivery
Kromschroder Ignition transformer TZI 8-20/33QT 84391141
Brand Kromschroder
Key specifications
| Supply voltage | 120 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Ingress protection | IP00 |
| Certification | CE, UL, CSA |
| Fuel | gas and gas-oil |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Cable insulation type | silicone |
| Operating phase | only during ignition period |
| Output type | single-pole, to ground |
| Housing type | compact |
| Installation type | control cabinet |
| Secondary current | 16–20 mA |
| Duty cycle | 33% |
| Frequency | 50–60 Hz |
| Country of origin | Germany |
241.20EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This Kromschroder ignition transformer (model TZI 8-20/33QT) steps up a 120 V AC supply to a secondary voltage of 8 kV, providing 16–20 mA at 50–60 Hz. It has a duty cycle of 33% and a single-pole output to ground. The transformer operates only during the ignition period and is intended for installation in a control cabinet. It is suitable for gas and gas-oil burners and carries CE, UL, and CSA certifications.
Choosing and fitting
Parts of this type are selected by secondary voltage and current, primary voltage, duty cycle, mounting style, terminal type, and cable connector pattern. Before ordering, confirm that the primary voltage matches the burner supply and that the mounting pattern and terminal arrangement fit the existing bracket and wiring. The ignition cable between the transformer and electrode must be silicone-insulated to withstand high voltage and heat.
Signs of failure
A common failure mode is a hardened or cracked ignition cable that leaks the spark to earth, which may be mistaken for a faulty transformer. The burner may fail to ignite or show intermittent ignition. Check the cable and electrode condition before replacing the transformer.
All specifications
| Supply voltage | 120 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Ingress protection | IP00 |
| Certification | CE, UL, CSA |
| Fuel | gas and gas-oil |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Cable insulation type | silicone |
| Operating phase | only during ignition period |
| Output type | single-pole, to ground |
| Housing type | compact |
| Installation type | control cabinet |
| Secondary current | 16–20 mA |
| Duty cycle | 33% |
| Frequency | 50–60 Hz |
| Country of origin | Germany |
Part numbers
| SKU | 84391141 |
|---|---|
| Additional article | 624.820.037 |
| Model | TZI 8-20/33QT |
Similar parts
378.00 EURexcl. VAT · import VAT and duties on delivery
220.80 EURexcl. VAT · import VAT and duties on delivery
417.00 EURexcl. VAT · import VAT and duties on delivery
249.00 EURexcl. VAT · import VAT and duties on delivery
378.00 EURexcl. VAT · import VAT and duties on delivery
241.20 EURexcl. VAT · import VAT and duties on delivery
448.73 EURexcl. VAT · import VAT and duties on delivery