492.48 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Mounting thread size | must match the existing installation |
|---|---|
| Sight tube length | must match the existing installation |
| Wiring polarity | verify the wiring polarity |
| Operating voltage | verify the cell's operating voltage |
190.44EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Brahma UV cell 18210068 is a flame detector that responds to ultraviolet radiation emitted by flames, used in gas and oil burner flame-proving circuits. It is compatible with Brahma 18210068 and Sylvania P630. 88 models. The cell is designed for precise control of gas burner valves, providing opening and closing when voltage is applied, with high thermal resistance and durable insulation. Its design resists vibrations and mechanical loads. The cell is typically mounted on a flame-sight tube or directly on the burner housing, aimed at the combustion zone.
Further details
| Compatibility with burner control | matching the signal type, not just the physical fit |
|---|---|
| Installation requirement | ensure the power is off and the burner control is safe to work on; check sight path is clear of soot, carbon, or oil deposits; align the cell to see the steady flame, not the spark or a reflected source |
| Operating Principle | responds to ultraviolet radiation emitted by the flame |
| Operating life | finite operating life; sensitivity may degrade over time |
Choosing and fitting
When selecting a UV cell for replacement, key parameters include spectral sensitivity range (typically 190–290 nm), response time, supply voltage, and output signal type (current or voltage pulse). The physical mounting-thread size, sight tube length, and connector or flying leads must match the existing installation; an incorrect fit can cause false readings or no flame signal. Ensure the sight path is clear of soot, carbon, or oil deposits, and align the cell to see the steady flame, not the spark or reflected source. Verify wiring polarity and operating voltage against the burner control's requirements.
Signs of failure
UV cells have a finite operating life; sensitivity may degrade over time due to solarisation of the quartz window or contamination by combustion residues. Symptoms include burner lockout during start-up or loss of flame signal during operation. A dirty lens can mimic a failing cell, so check and clean the sight path. If lockout occurs after replacement, verify wiring polarity, operating voltage, and compatibility with the burner control.
Fits equipment
Sylvania P630.88
All specifications
| Mounting thread size | must match the existing installation |
|---|---|
| Sight tube length | must match the existing installation |
| Wiring polarity | verify the wiring polarity |
| Operating voltage | verify the cell's operating voltage |
Part numbers
| SKU | 18210068 |
|---|---|
| Additional article | 920.973.004 |
Similar parts
772.20 EURexcl. VAT · import VAT and duties on delivery
384.60 EURexcl. VAT · import VAT and duties on delivery
1695.60 EURexcl. VAT · import VAT and duties on delivery
700.22 EURexcl. VAT · import VAT and duties on delivery
179.04 EURexcl. VAT · import VAT and duties on delivery
194.11 EURexcl. VAT · import VAT and duties on delivery