Key specifications
| Flame sensing method | ionisation electrode |
|---|---|
| Ignition system type | ignition electrode and ionisation electrode |
| Pilot flame mode | permanent or intermittent flame |
| Common failure mode | eroded spark tips |
| Insulator material | ceramic |
| Spark gap drift | drifting electrode gap |
72.00EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This pilot burner carries a small permanent or intermittent pilot flame. The flame lights the main burner and provides a flame signal for the control system. Flame sensing is performed by an ionisation electrode, while ignition uses both an ignition electrode and an ionisation electrode. The insulator is made of ceramic.
Further details
| Application | gas boilers, burners, fireplaces, industrial heat engineering equipment, water heaters |
|---|---|
| Common wear patterns | eroded spark tips, cracked ceramic insulators, soot build-up, drifting electrode gap |
Choosing and fitting
Parts of this type are selected by matching electrode geometry—length, bend, insulator diameter, and spark gap—to the burner series they were shaped for. The mounting flange must also align with the burner head. In systems where the pilot burner is integrated, the unit typically houses both the ignition electrode and the ionisation electrode, though the specific arrangement depends on the burner design. Always verify the burner model and compare the physical dimensions of the replacement directly against the original unit.
Signs of failure
Common wear patterns include eroded spark tips, cracked ceramic insulators, soot build-up from incomplete combustion, and a drifting electrode gap that lengthens the ignition time. These signs may be visible when inspecting the burner.
All specifications
| Flame sensing method | ionisation electrode |
|---|---|
| Ignition system type | ignition electrode and ionisation electrode |
| Pilot flame mode | permanent or intermittent flame |
| Common failure mode | eroded spark tips |
| Insulator material | ceramic |
| Spark gap drift | drifting electrode gap |
Part numbers
| SKU | Q382A2009/B |
|---|---|
| Additional article | 534.205.901 |
Similar parts
465.00 EURexcl. VAT · import VAT and duties on delivery
465.00 EURexcl. VAT · import VAT and duties on delivery
15.00 EURexcl. VAT · import VAT and duties on delivery
1041.60 EURexcl. VAT · import VAT and duties on delivery
1541.40 EURexcl. VAT · import VAT and duties on delivery
1211.40 EURexcl. VAT · import VAT and duties on delivery
795.00 EURexcl. VAT · import VAT and duties on delivery