Key specifications
| Setting range | 8–100 mbar |
|---|---|
| Connection thread | thread or hose spigot |
| Protection class (IP) | IP 00 |
| Maximum working pressure | 100 |
| Connection type | via a din plug |
| Factory setting | 8 mbar |
| Medium | air or gas |
| Adjustable switching range | required switching range |
| Differential | required switching range and differential |
| Contact rating | electrical contact rating |
| Ambient temperature, max | 75 °C |
| Ambient temperature, min | -10 °C |
Lowest price in the 30 days before the price drop
54.96EUR
in stock · 4excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell pressure switch 45900438-301B is a device used to control excess pressure in a working medium containing combustible gases. Its operating range is from 8 to 100 mbar, with a factory setting of 8 mbar. The maximum working pressure is 100 mbar. It has a dust and moisture protection class of IP 00 and connects via a DIN plug. The operating ambient temperature range is from -10 to +75 °C. This switch is a component in burner and boiler control systems, verifying that pressure or airflow remains within the permitted operating band.
Further details
| Application | component used in burner and boiler control systems to verify that pressure or airflow remains within the permitted operating band |
|---|---|
| Approval class | applicable approval class for the burner or boiler |
| Function | used to control excess pressure in a working medium containing combustible gases |
| Role in system | air pressure switch wired into safety circuit; gas pressure switch guards against supply pressure outside safe range |
| Typical failures | torn diaphragm, blocked or leaking impulse tube, drifted setpoint |
Choosing and fitting
Parts of this type are selected according to the medium (air or gas), the required switching range and differential, the type of connection (thread or hose spigot), electrical contact rating, and the applicable approval class for the burner or boiler. When replacing, ensure the switch's setpoint and differential match the original's functional parameters, and that the connection type and thread or hose spigot fit the existing installation.
Signs of failure
Typical failure modes include a torn diaphragm, a blocked or leaking impulse tube, or a drifted setpoint. Any of these faults will cause the burner to lock out in a way that can appear similar to an ignition problem. Check the diaphragm, impulse tube, and setpoint calibration when such symptoms occur.
All specifications
| Setting range | 8–100 mbar |
|---|---|
| Connection thread | thread or hose spigot |
| Protection class (IP) | IP 00 |
| Maximum working pressure | 100 |
| Connection type | via a din plug |
| Factory setting | 8 mbar |
| Medium | air or gas |
| Adjustable switching range | required switching range |
| Differential | required switching range and differential |
| Contact rating | electrical contact rating |
| Ambient temperature, max | 75 °C |
| Ambient temperature, min | -10 °C |
Part numbers
| SKU | 45900438-301B |
|---|---|
| Additional article | 534.676.903 |
Similar parts
72.00 EURexcl. VAT · import VAT and duties on delivery
624.00 EURexcl. VAT · import VAT and duties on delivery
187.20 EURexcl. VAT · import VAT and duties on delivery
631.80 EURexcl. VAT · import VAT and duties on delivery
172.80 EURexcl. VAT · import VAT and duties on delivery
82.80 EURexcl. VAT · import VAT and duties on delivery