Honeywell Gas boiler control unit S4561B1039U(2)

SKU S4561B1039U(2) Brand Honeywell
Honeywell logo — Honeywell spare parts for burners and boilers Brand Honeywell
Buy Honeywell Gas boiler control unit S4561B1039U(2)

Key specifications

Supply voltage220–240 V
Flame detector typeionisation
Frequency50 Hz
Power consumption10 W
Applicationused in modern wall-hung boilers
Safety standardEN 298
Spark frequency5 Hz
Flame powerDT L
Gas valve current1 A
Control typePCB-type burner control
Flame detection methodionisation
Burner typeatmospheric gas burner
Spark ignition size2.8 mm
Flame extinguisher and grounding tip size6.3 mm
Minimum open spark voltage15 kV
Safety timer setting0 s
Self-check timetcheck
Waiting periodtw
Safe timets
PCB dimensions105 mm
Mounting holes4
External reset, alarm, high limit connectionpossible
Non-volatile blockingpossible
Alarm in absence of heatyes
Protective impedance on flame extinguisheryes
Extended spark ignition or quick startpossible
all specifications (26) ↓

218.96EUR

in stock · 1

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell S4561B1039U(2) is a PCB-type burner control unit designed for automatic ignition and flame supervision of atmospheric gas burners in wall-hung boilers, complying with EN 298. It operates at 220–240 V AC, 50 Hz, with a power consumption of 10 W. The unit uses ionisation flame detection and provides spark ignition at 5 Hz with a minimum open spark voltage of 15 kV. It features a safety timer setting of 0 s, supports external reset and high-limit alarm, and includes non-volatile blocking and alarm in absence of heat. The PCB dimensions are 105 mm with 4 mounting holes, and it fits Pegasus F2/F3 boilers.

Further details

Application (D) bi or (I) p d(D) bi or (I) p d
Electrical Connectionpolyhedral molex 3003 connector compatible with the molex 3001 connector
Flame Failure Behaviorgo to lockout if a fault is detected
Flame indication relaySPST for SELV circuits or SPDT for line voltage circuits
Flame loss sequencecomplete sequence of operations after flame loss
Ignition Typeboth with pilot and direct ignition
Ignition capabilityup to (G) round, (CL) closed loop or (N) one CL
Installation requirementmust be installed outside of access
RFI shielding requirementmust be installed in a sufficiently shielded room
Recommended installation conditionlow ambient temperature and minimal thermal radiation
Repair requirementrepair must be carried out by Honeywell
Safety Featureall burner control protection functions are integrated into a reliable system
Thermostat connection recommendationconnect upper limit thermostat in series with comfort regulators

Choosing and fitting

Parts of this type are selected by matching the supply voltage, frequency, and flame detection method (ionisation) to the boiler's control system. The PCB dimensions and mounting hole pattern must align with the boiler's enclosure. The gas valve current rating (up to 1 A) and connector type must be compatible. Always verify the specific model compatibility with the boiler make and model before ordering.

Signs of failure

Common failures include loss of flame detection due to a faulty ionisation probe or wiring, leading to repeated ignition attempts or lockout. Spark ignition may fail if the spark electrode gap is incorrect or the high-voltage cable is damaged. The unit may also fail to start if the safety timer or self-check sequence is interrupted by a faulty sensor or valve. Check for visible damage, loose connections, and correct grounding.

Fits equipment

Pegasus F2 /F3Ferroli Pegasus F2/F3

All specifications

Supply voltage220–240 V
Flame detector typeionisation
Frequency50 Hz
Power consumption10 W
Applicationused in modern wall-hung boilers
Safety standardEN 298
Spark frequency5 Hz
Flame powerDT L
Gas valve current1 A
Control typePCB-type burner control
Flame detection methodionisation
Burner typeatmospheric gas burner
Spark ignition size2.8 mm
Flame extinguisher and grounding tip size6.3 mm
Minimum open spark voltage15 kV
Safety timer setting0 s
Self-check timetcheck
Waiting periodtw
Safe timets
PCB dimensions105 mm
Mounting holes4
External reset, alarm, high limit connectionpossible
Non-volatile blockingpossible
Alarm in absence of heatyes
Protective impedance on flame extinguisheryes
Extended spark ignition or quick startpossible

Part numbers

SKUS4561B1039U(2)
Additional article534.412.035

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
218.96 EUR 1