Honeywell Gas control unit MMG810.1 mod.43 0642520

SKU 0642520 Model MMG810.1 mod.43 Brand Honeywell
Honeywell logo — Honeywell spare parts for burners and boilers Brand Honeywell
Buy Honeywell Gas control unit MMG810.1 mod.43 0642520

Key specifications

Supply voltage220–240 V
Safety time3 s
Protection class (IP)IP44
Waiting time9 s
Air proving switch6.0 s
Time delay term.6 / term.C10 s
Power consumption10 W
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Weight incl. wiring base350 kg
Pre-purge time40 s
Pre-ignition time3 s
Net weight0.35 kg
all specifications (13) ↓

816.30EUR

in stock · 3

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell MMG810.1 mod.43 is a gas control unit designed for forced draft and combined gas and oil burners of any nominal size. It operates with a supply voltage of 220–240 V and has a power consumption of 10 W. The unit features a waiting time of 9 s, a pre-purge time of 40 s, a pre-ignition time of 3 s, and a safety time of 3 s. It includes an air proving switch with a reaction time of 6.0 s and a time delay of 10 s between terminals 6 and C. The control unit has an amplifier sensitivity of 1 µA and requires a minimum current of 5 µA from a UV tube or ionisation probe. It weighs 0.35 kg net and has a protection class of IP44.

Further details

AC frequency variationsresult in proportional timing deviations
Classified acc. to EN 298BTLLXN
Flame Detectorionisation probe, UV sensor, infrared flicker detector
Flame detector cablemax. 20 m cable length
Fuse ratingmax. 10 A rapid, 6 A slow
Infrared flare detectorIRD 1020
Insulation standardIP 44
Mounting attitudeany
Permissable ambient temp.-20° C... +60°C
Reset delaynone

Choosing and fitting

When selecting a replacement control box for a burner, ensure the supply voltage, timing sequences, and safety times match the burner's specifications. The control box must be compatible with the flame detector type (ionisation probe, UV sensor, or infrared flicker detector) and the wiring configuration. Check the mounting dimensions and protection class to fit the existing enclosure. Verify the power consumption and current requirements align with the burner's electrical system.

Signs of failure

Common failures in gas control units include failure to start, intermittent operation, or lockout due to flame detection issues. Symptoms may include the burner not igniting, shutting down after a short period, or displaying an error code. Check the flame detector, wiring connections, and supply voltage for faults. Also inspect the air proving switch and ensure proper airflow before the unit initiates the pre-purge cycle.

All specifications

Supply voltage220–240 V
Safety time3 s
Protection class (IP)IP44
Waiting time9 s
Air proving switch6.0 s
Time delay term.6 / term.C10 s
Power consumption10 W
Amplifier sensitivity1 µA
Min. current from UV tube or ionisation probe5 µA
Weight incl. wiring base350 kg
Pre-purge time40 s
Pre-ignition time3 s
Net weight0.35 kg

Part numbers

SKU0642520
Additional article852.124.066
ModelMMG810.1 mod.43

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
816.30 EUR 1