Honeywell Gas boiler control unit S4560A1008U

SKU S4560A1008U Model S4560A1008 Brand Honeywell
Honeywell logo — Honeywell spare parts for burners and boilers Brand Honeywell
Buy Honeywell Gas boiler control unit S4560A1008U

Key specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeflame sensor rod
Protection class (IP)IP40
Connector typeMolex 3001 multi-edge connector
Cycle typeintermittent
Behaviour in the event of flame failure during operationrepeats ignition sequence
Flame relay outputyes
Fan supportyes
Frequency50 Hz
Ignition typedirect
Internal ignitionno
Lockout typenon-volatile blocking
Maintenance freeyes
Power consumption10 W
Reset button typeexternal or internal reset button
Applicationatmospheric gas burners
Blocking in absence of etheryes
Safety featureManual reset lockout
Safety standardEN 298
Time ts10 s
FuelGas
Restart behaviorrepeats ignition sequence
Reset wait time15 s
Blocking during flame simulationyes
Gas valve + GPS connectionyes
Input signal protection from resetyes
Quick launch optionyes
LPG valve supportyes
Maximum thermal relay requiredyes
Shielded ignition cables requiredyes
Length137 mm
Width86 mm
Height49 mm
EN 298 complianceyes
Application typeatmospheric gas burners
Flame monitoringflame sensor rod
Waiting time0 s
TC test period tP2.5 s
Mounting hole diameter4.5 mm
Spark terminal size2.8 mm
Flame extinguisher tip size6.3 mm
External fuseyes
Rigid lockingyes
High temperature effectshortens service life
Gas pressure monitoringyes
TTB relay reset requiredyes
all specifications (47) ↓

315.00EUR

in stock · 1

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell S4560A1008U is a gas boiler control unit for atmospheric gas burners. It operates in intermittent cycle mode with direct ignition and flame monitoring via a sensor rod. The unit conforms to EN 298 and features a non-volatile lockout with manual reset. It operates at 220–240 V, 50 Hz, with a power consumption of 10 W and a safety time of 10 s. The control box has a Molex 3001 multi-edge connector, supports a fan, and is rated IP40. It is maintenance-free and requires external fuses and a thermal relay.

Choosing and fitting

Control boxes of this type are selected by matching the supply voltage, frequency, safety time, and connector configuration of the existing installation. Before ordering, compare the mounting dimensions and terminal sizes with the original unit. During installation, provide external fuses for safety and place the controller away from heat and radiation. The overall enclosure protection must be at least IP40, and spark ignition cables must be shielded. These controllers have no user-serviceable parts; do not attempt internal repairs.

Signs of failure

Typical failure of these control units is a lockout when the flame is not detected within the safety time, often caused by a dirty or misaligned flame sensor rod. If the flame goes out during operation, the unit repeats the ignition sequence. Lockout is non-volatile and requires manual reset via the external or internal reset button. If the first reset fails, wait at least 15 seconds before again attempting reset.

All specifications

Supply voltage220–240 V
Safety time10 s
Flame detector typeflame sensor rod
Protection class (IP)IP40
Connector typeMolex 3001 multi-edge connector
Cycle typeintermittent
Behaviour in the event of flame failure during operationrepeats ignition sequence
Flame relay outputyes
Fan supportyes
Frequency50 Hz
Ignition typedirect
Internal ignitionno
Lockout typenon-volatile blocking
Maintenance freeyes
Power consumption10 W
Reset button typeexternal or internal reset button
Applicationatmospheric gas burners
Blocking in absence of etheryes
Safety featureManual reset lockout
Safety standardEN 298
Time ts10 s
FuelGas
Restart behaviorrepeats ignition sequence
Reset wait time15 s
Blocking during flame simulationyes
Gas valve + GPS connectionyes
Input signal protection from resetyes
Quick launch optionyes
LPG valve supportyes
Maximum thermal relay requiredyes
Shielded ignition cables requiredyes
Length137 mm
Width86 mm
Height49 mm
EN 298 complianceyes
Application typeatmospheric gas burners
Flame monitoringflame sensor rod
Waiting time0 s
TC test period tP2.5 s
Mounting hole diameter4.5 mm
Spark terminal size2.8 mm
Flame extinguisher tip size6.3 mm
External fuseyes
Rigid lockingyes
High temperature effectshortens service life
Gas pressure monitoringyes
TTB relay reset requiredyes

Part numbers

SKUS4560A1008U
Additional article534.412.141
ModelS4560A1008
Type designationS4560B1089U

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
315.00 EUR 1