Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Reset method | button or power interruption |
| LPG valve support | yes |
| TC test period tP | performed before pre-purge |
| Extended ignition time | addable after flame established |
| Restart behavior | repeats starting sequence with pre-purging |
| Auxiliary fan | yes |
| Fuel | Gas |
| Application | dbi or ip |
| Safety standard | EN 298, EN 60730-1 |
| Safety feature | manual reset lockout |
| Ignition type | direct or pilot ignition |
| Reset wait time | 15 s |
| Connector on top | yes |
| Compatible gas valves | vk41 series gas regulators |
| Flame sensor | flame sensor rod |
| Reset button type | own/external reset button |
| Airflow control relay | present |
| Supported ignition systems | dbi and ip |
| Controlled components | main and pilot burners |
| EN 298 compliance | yes |
| Gas regulator compatibility | vk41 series gas regulators |
| Ignition transformer voltage | built-in or external |
210.00EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a gas boiler control unit from Honeywell, catalog number S4565C3116B, belonging to the category of control boxes. It operates on a supply voltage of 220–240 V and is designed for gas-fired equipment with either direct burner ignition (dbi) or pilot burner ignition (ip). The unit conforms to EN 298 and EN 60730-1 and features a manual reset lockout. It performs a test period (tp) before pre-purge and supports flame detection via a flame sensor rod. It is compatible with VK41 series gas regulators and includes a connector on top for simplified wiring. The reset wait time between attempts is 15 seconds, and reset can be done by button or power interruption.
Further details
| Airflow control | relay detects airflow and starts fan |
|---|---|
| Integrated Protection | all burner protection functions are integrated into a reliable system |
| Standby behavior | remains in standby mode with the fan running |
Choosing and fitting
When selecting a replacement control box of this type, check the supply voltage and ignition system type (direct spark or pilot burner). Variants with suffix C include an auxiliary fan, so confirm that the replacement matches the required fan support. The unit mounts onto the gas regulator via a connector on the top and can be oriented within 90° in any direction from the vertical. Ensure the wiring to the gas valve, ignition transformer, and flame sensor matches the original layout.
Fits equipment
Honeywell VK41
Unox XVC 315GUnox XBC 815G
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Reset method | button or power interruption |
| LPG valve support | yes |
| TC test period tP | performed before pre-purge |
| Extended ignition time | addable after flame established |
| Restart behavior | repeats starting sequence with pre-purging |
| Auxiliary fan | yes |
| Fuel | Gas |
| Application | dbi or ip |
| Safety standard | EN 298, EN 60730-1 |
| Safety feature | manual reset lockout |
| Ignition type | direct or pilot ignition |
| Reset wait time | 15 s |
| Connector on top | yes |
| Compatible gas valves | vk41 series gas regulators |
| Flame sensor | flame sensor rod |
| Reset button type | own/external reset button |
| Airflow control relay | present |
| Supported ignition systems | dbi and ip |
| Controlled components | main and pilot burners |
| EN 298 compliance | yes |
| Gas regulator compatibility | vk41 series gas regulators |
| Ignition transformer voltage | built-in or external |