Kromschroder Burner control unit BCU370WI2FEU0D3 88600619
Brand Kromschroder
Key specifications
| Flame detector type | UV sensor or ionisation sensor |
|---|---|
| Max. number of operating cycles | 250000 |
| Burner start-up attempts | 2 |
| Switch-on delay time tE | 0 s |
| Weight | 1800 g |
| Maximum length of ionisation/UV cable | 50 m |
| Ambient temperature | -20–60 °C |
| Fuel | Gas |
| Cycle type | Intermittent or continuous |
| Flame proving period 1, burner/pilot tFS1 | 2 s |
| Flame proving period 2, main burner tFS2 | 2 s |
| Controller enable signal delay time tRF | 10 s |
| TC test period tP | 20 s |
| Fan run-up time tGV | 0 s |
| Ignition type | Integrated electronic |
| Valve control type | Three-point step |
| Minimum burner pause time tBP | 60 s |
| Burner switch-off threshold | 1 µA |
| UVS check | Off |
| Password protection | User-defined |
| Air monitoring during pre-purge | Off |
| Pre-purge on each start-up | Off |
| Pre-ignition time tVZ | 1 s |
| Control features | Automatic |
| Safety time 1, burner/pilot burner start-up tSA1 | 5 s |
| Safety time 2, main burner start-up tSA2 | 2 s |
| Safety time during operation tSB | 1 s |
| Pre-purge time tPV | 30 s |
| Post-purge time tPN | 100 s |
| Mounting feature | Plug-in |
| Design features | Impact-resistant and heat-resistant plastic housing |
| Original equipment manufacturer | Kromschroder |
| Flame failure response | Restart |
| Ingress protection | IP54 |
| Maximum length of ignition cable | 1 m |
| Fan control | Double-pole, 3 A relay |
| Digital input function | Integrated tightness control |
| Operating time in manual mode | Unlimited |
| Air monitoring during operation | Off |
| Min. gas pressure monitoring | Off |
| Quick start | Starts in closed position |
| V2 during burner operation | On |
2661.60EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This burner control unit is designed for industrial forced draught burners fired by gas and can operate in intermittent or continuous mode. It supervises the flame via a UV or ionisation sensor (max. cable length 50 m) and provides an integrated electronic ignition with a max. ignition cable of 1 m. The unit allows 2 start-up attempts; pre-ignition time is 1 s, safety time for burner/pilot start-up (TSA1) is 5 s, flame-proving period (TFS1) is 2 s, safety time for main burner start-up (TSA2) is 2 s, and flame-proving period for main burner (TFS2) is 2 s. Pre-purge time is 30 s, post-purge time is 100 s, and the controller enable signal delay (TRF) is 10 s. It features a three-point step valve control, a double-pole 3 A fan relay, integrated tightness control through a digital input, and a flame failure response of restart. The impact- and heat-resistant plastic housing fulfils IP54, weighs 1800 g, operates in ambient temperatures from -20 to 60 °C, and is rated for a maximum of 250,000 operating cycles.
Further details
| Air pressure check | During pre-purge and operation by external air pressure switch DL |
|---|---|
| Application | Forced draught burners (directly ignited or with pilot burner) |
| Behaviour in the event of flame failure during operation | restart |
| Connection type | Terminals, earthing strip, pre-wired neutral bus |
| Enclosure | IP 54 pursuant to IEC 529 |
| Flame control | ionization control (continuous or intermittent operation) or UV control |
| Flame control methods | Ionization (continuous or intermittent) or UV (intermittent with UVS) |
| Flame signal for Ionization control | 1 – 28 μA, UV control: 1 – 35 μA |
| Mains voltage | 230 V AC, 50/60 Hz |
| V2 during burner operation | On |
All specifications
| Flame detector type | UV sensor or ionisation sensor |
|---|---|
| Max. number of operating cycles | 250000 |
| Burner start-up attempts | 2 |
| Switch-on delay time tE | 0 s |
| Weight | 1800 g |
| Maximum length of ionisation/UV cable | 50 m |
| Ambient temperature | -20–60 °C |
| Fuel | Gas |
| Cycle type | Intermittent or continuous |
| Flame proving period 1, burner/pilot tFS1 | 2 s |
| Flame proving period 2, main burner tFS2 | 2 s |
| Controller enable signal delay time tRF | 10 s |
| TC test period tP | 20 s |
| Fan run-up time tGV | 0 s |
| Ignition type | Integrated electronic |
| Valve control type | Three-point step |
| Minimum burner pause time tBP | 60 s |
| Burner switch-off threshold | 1 µA |
| UVS check | Off |
| Password protection | User-defined |
| Air monitoring during pre-purge | Off |
| Pre-purge on each start-up | Off |
| Pre-ignition time tVZ | 1 s |
| Control features | Automatic |
| Safety time 1, burner/pilot burner start-up tSA1 | 5 s |
| Safety time 2, main burner start-up tSA2 | 2 s |
| Safety time during operation tSB | 1 s |
| Pre-purge time tPV | 30 s |
| Post-purge time tPN | 100 s |
| Mounting feature | Plug-in |
| Design features | Impact-resistant and heat-resistant plastic housing |
| Original equipment manufacturer | Kromschroder |
| Flame failure response | Restart |
| Ingress protection | IP54 |
| Maximum length of ignition cable | 1 m |
| Fan control | Double-pole, 3 A relay |
| Digital input function | Integrated tightness control |
| Operating time in manual mode | Unlimited |
| Air monitoring during operation | Off |
| Min. gas pressure monitoring | Off |
| Quick start | Starts in closed position |
| V2 during burner operation | On |
Part numbers
| SKU | 88600619 |
|---|---|
| Additional article | 624.103.158 |
| Model | BCU370WI2FEU0D3 |
Similar parts
1287.60 EURexcl. VAT · import VAT and duties on delivery
2661.60 EURexcl. VAT · import VAT and duties on delivery
3135.60 EURexcl. VAT · import VAT and duties on delivery
2591.40 EURexcl. VAT · import VAT and duties on delivery
2406.00 EURexcl. VAT · import VAT and duties on delivery
2661.60 EURexcl. VAT · import VAT and duties on delivery
2679.00 EURexcl. VAT · import VAT and duties on delivery