Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | Photocell |
| Frequency | 50–60 Hz |
| Application | Riello burners |
| Fuel | Liquid fuel |
| Ambient temperature | 0–40 °C |
| Maximum length of ionisation/UV cable | 1 m |
| Cycle type | intermittent |
| Safety standard | EN267 |
| Flame sensor type | Ionisation electrode or UV detector |
| Original equipment manufacturer | Siemens |
| Safety time 1, burner/pilot burner start-up tSA1 | 5 s |
| Mounting feature | Plug in base |
| Control features | Automatic |
| Design features | increased anti-interference capability |
| Control design | microprocessor-based |
| Flame failure response | lockout after 3 flame losses |
| Reset button max pressure | 10 N |
| Ion pin to ground minimum resistance | 50 MΩ |
| Burner stage control | one-stage and two-stage |
203.61EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This burner control unit (RMO88.53C2) is a microprocessor-based oil burner control for Riello burners, supplied by Siemens. It is designed for 220–240 V, 50–60 Hz, intermittent duty, and meets EN267. It has a 5 s safety time at start-up and a flame detector type of photocell. It accepts an ionisation electrode or UV detector as flame sensor. It provides one-stage and two-stage control, mounts on a plug-in base, and is rated for 0–40 °C ambient. It locks out after three flame losses.
Further details
| Component type | Burner control unit / Flame safeguard / Control box |
|---|---|
| Control functions | Pre-purge, ignition spark, gas valve/oil pump control, flame monitoring, safety lockout |
| Interface compatibility | Air pressure switch and modulation controls |
| Selection criteria | Supply voltage, safety time, flame sensor type |
Choosing and fitting
Controls of this type are selected by supply voltage, safety time and the flame sensor type they accept. Before ordering, verify that the wiring base matches the existing socket and that the timing and reset behaviour suit the burner. During installation, keep the ionisation/UV cable no longer than 1 m, ensure the ion pin-to-ground resistance is at least 50 MΩ, and do not press the reset button with more than 10 N. Disconnect power before rewiring, do not confuse line and neutral, and keep controller terminals well insulated from the ignition cable.
Signs of failure
When flame is lost, this class of control normally attempts a restart; after three flame losses it locks out. Fault, false flame and low-voltage conditions are indicated by the alarm lights. A flame sensor cable longer than 1 m, a contaminated sensor, or an ion-pin-to-ground resistance below 50 MΩ can prevent flame confirmation and lead to lockout. Check the sensor and cable insulation before replacing the control.
Fits equipment
Riello RL34/1Riello RL44/1Riello RL28/1Riello RL38/1Riello RL34Riello RL44Riello RL28Riello RL38Riello RL50Riello RL64Riello RL70Riello RL100Riello RL130Riello RL190
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | Photocell |
| Frequency | 50–60 Hz |
| Application | Riello burners |
| Fuel | Liquid fuel |
| Ambient temperature | 0–40 °C |
| Maximum length of ionisation/UV cable | 1 m |
| Cycle type | intermittent |
| Safety standard | EN267 |
| Flame sensor type | Ionisation electrode or UV detector |
| Original equipment manufacturer | Siemens |
| Safety time 1, burner/pilot burner start-up tSA1 | 5 s |
| Mounting feature | Plug in base |
| Control features | Automatic |
| Design features | increased anti-interference capability |
| Control design | microprocessor-based |
| Flame failure response | lockout after 3 flame losses |
| Reset button max pressure | 10 N |
| Ion pin to ground minimum resistance | 50 MΩ |
| Burner stage control | one-stage and two-stage |
Part numbers
| SKU | 3013071 |
|---|---|
| Additional article | 884.124.002 |
| Model | RMO88.53C2 |
| Type designation | LMO88.530C2RL |
Fits burners · 20
Riello PRESS 100
Oil · 285–1140 kW
All parts for this burner →
Riello PRESS 30
Oil · 85–342 kW
All parts for this burner →
Riello PRESS 300 T/G TC FS1
Oil · 1779–3560 kW
All parts for this burner →
Riello PRESS 45
Oil · 114–513 kW
All parts for this burner →
Riello PRESS 60
Oil · 171–684 kW
All parts for this burner →
Riello RL 100
Oil · 356–1186 kW
All parts for this burner →
Riello RL 130
Oil · 486–1540 kW
All parts for this burner →
Riello RL 190
Oil · 759–2443 kW
All parts for this burner →
Riello RL 190 TC FS1
Oil · 759–2443 kW
All parts for this burner →
Riello RL 250
Oil · 600–2700 kW
All parts for this burner →
Riello RL 28/1
Oil · 178–332 kW
All parts for this burner →
Riello RL 300/B
Oil · 600–3550 kW
All parts for this burner →
Riello RL 34
Oil · 97–395 kW
All parts for this burner →
Riello RL 34/1
Oil · 107–398 kW
All parts for this burner →
Riello RL 400/B
Oil · 1000–4450 kW
All parts for this burner →
Riello RL 44
Oil · 155–485 kW
All parts for this burner →
Riello RL 50
Oil · 148–593 kW
All parts for this burner →
Riello RL 50 TC
Oil · 148–593 kW
All parts for this burner →
Riello RL 50 TL
Oil · 148–593 kW
All parts for this burner →
Riello RL 70
Oil · 255–830 kW
All parts for this burner →
Similar parts
1660.80 EURexcl. VAT · import VAT and duties on delivery
923.55 EURexcl. VAT · import VAT and duties on delivery
1287.60 EURexcl. VAT · import VAT and duties on delivery
16.92 EURexcl. VAT · import VAT and duties on delivery
152.40 EURexcl. VAT · import VAT and duties on delivery