Key specifications
| Detection principle | photocell |
|---|---|
| Cable length | 635 mm |
| Catalogue article numbers | 18210018, 4031.018, 246.901.016 |
| Application type | luminous flames |
| Detection principle | light detection |
| FC7/A designation | fc7/a blue |
| Flame detection method | direct line-of-sight |
Lowest price in the 30 days before the price drop
22.32EUR
in stock · 45excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Brahma FC7/A photocell flame sensor with a 635 mm cable, designed for flame detection in luminous flames. It operates by light detection and requires direct line-of-sight to the flame. This model is identified by article numbers 18210018, 4031.018, and 246.901.016. It is compatible with Master 4031.018, Master BV680, Master MAX15TC, and Master MAX20TL air heaters.
Further details
| Application | flame detection on oil and industrial burners |
|---|---|
| Replacement check | same detection principle, cable length, connector, and mounting dimensions |
| Selection parameters | detection principle, spectral range, response time, cable length, connector type, mounting arrangement |
| Typical Failure Modes | contaminated optical window, aged cell, damaged cable |
Choosing and fitting
When selecting a replacement photocell of this type, ensure the detection principle (light detection), cable length, connector type, and mounting dimensions match the original component. The sensor must be positioned with a clear line-of-sight to the flame, typically in a viewing tube or sleeve. Verify the mounting arrangement and spectral response to match the burner control.
Signs of failure
Common failure modes include a contaminated optical window, an aged cell producing a weakened signal, or a damaged cable or sheath. Symptoms may include the burner failing to start or shutting down during operation due to lack of flame confirmation. Check the optical window for dirt or damage, and test the sensor's output signal.
Fits equipment
Master 4031.018Master BV680Master MAX15TCMaster MAX20TL
All specifications
| Detection principle | photocell |
|---|---|
| Cable length | 635 mm |
| Catalogue article numbers | 18210018, 4031.018, 246.901.016 |
| Application type | luminous flames |
| Detection principle | light detection |
| FC7/A designation | fc7/a blue |
| Flame detection method | direct line-of-sight |
Part numbers
| SKU | 18210018 |
|---|---|
| Additional article | 246.901.016 |
| Model | FC7/A |