Key specifications
| Supply voltage | 230 V |
|---|---|
| Weight | 800 g |
| Nozzle diameter | 15 mm |
| Closing time | 1 s |
| Opening time | 1 sec |
| Gas group | 2 |
| Installation position | vertical and horizontal |
| Body material | die-cast aluminum |
| Cable gland | PG9 |
| Coil voltage type | DC (built-in rectifier) |
| Valve classification | A |
| Normal state | normally closed |
| Built-in filter | mesh filter at inlet |
| Pressure test points | pressure plugs |
| Application | civil and industrial |
| Opening type | fast, silent |
| Flow regulator | flow control |
| Silent operation | Yes |
| Variable opening modes | quick or slow opening |
| Flow adjustment | adjustment plugs |
| Power supply flexibility | AC and DC |
| Frequency | 50–60 Hz |
| Power consumption | 20 W |
| Flow capacity | 7.5 m³/h |
| Certification | CE, EN161 |
Lowest price in the 30 days before the price drop
97.38EUR
in stock · 2excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a normally closed solenoid gas valve for civil and industrial gas burner applications. It operates on 230 V AC supply at 50–60 Hz, drawing 20 W; the coil is DC through a built-in rectifier. Flow capacity is 7.5 m³/h, nozzle diameter 15 mm, and it opens and closes in 1 s. The body is die-cast aluminum and the valve can be mounted vertically or horizontally. It is classified as Class A, Group 2, includes an inlet mesh filter, and is certified to EN161.
Further details
| Electrical Connection | Quick-start connection for DIN43650-IP65 plug (GFD IP40) |
|---|---|
| Filter mesh retention | prevents particles larger than 1 mm |
Choosing and fitting
Valves of this type are installed in vertical or horizontal pipe runs, and the replacement must have the same connection method and supply voltage. The electrical hookup uses a quick-start DIN 43650/IP65 plug with a PG9 cable gland; check that the existing wiring and plug match. Before ordering, compare the gas group/class, flow capacity, nozzle diameter, and opening mode required by the burner, and verify whether the control circuit supplies AC or DC power.
All specifications
| Supply voltage | 230 V |
|---|---|
| Weight | 800 g |
| Nozzle diameter | 15 mm |
| Closing time | 1 s |
| Opening time | 1 sec |
| Gas group | 2 |
| Installation position | vertical and horizontal |
| Body material | die-cast aluminum |
| Cable gland | PG9 |
| Coil voltage type | DC (built-in rectifier) |
| Valve classification | A |
| Normal state | normally closed |
| Built-in filter | mesh filter at inlet |
| Pressure test points | pressure plugs |
| Application | civil and industrial |
| Opening type | fast, silent |
| Flow regulator | flow control |
| Silent operation | Yes |
| Variable opening modes | quick or slow opening |
| Flow adjustment | adjustment plugs |
| Power supply flexibility | AC and DC |
| Frequency | 50–60 Hz |
| Power consumption | 20 W |
| Flow capacity | 7.5 m³/h |
| Certification | CE, EN161 |
Part numbers
| SKU | 13923001 |
|---|---|
| Additional article | 246.322.073 |
| Model | EG12*SR*GFD |