Riello Ignition cable 3008490

SKU 3008490 Brand Riello
Riello logo — Riello spare parts for burners and boilers Brand Riello
Buy Riello Ignition cable 3008490

Key specifications

Conductor cross-section0.75-1.5
Insulation temperature classF or H
Connector includedYes
Soldering requiredNo
Flame detector typeIonisation
Voltage typeRectified voltage
all specifications (6) ↓

105.30EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This ionization cable for Riello gas boilers carries the low-voltage flame-signal current from the ionisation electrode to the burner control. The control applies a rectified voltage to the electrode during ignition, and the cable allows the small DC current from the flame to flow back. It has a conductor cross-section of 0.75–1.5 mm² and insulation temperature class F or H, suitable for proximity to the combustion head. Connectors are included, and no soldering is required for installation.

Further details

Applicationconnecting temperature sensors or ionization electrodes
Common failure modeInsulation brittleness or melting near the electrode
Connector matchingMatched by connector series, pin count, keying, conductor cross-section, insulation temperature class, overall length and terminal type
FunctionCarries low-voltage flame-signal current from ionisation electrode to burner control
Terminal type optionsStraight or angled plug, eyelet or spade on electrode end

Choosing and fitting

Ionization cables of this type are selected by connector series, pin count and keying, conductor cross-section (typically 0.75–1.5 mm²), insulation temperature class (often F or H), overall length, and terminal type. When replacing, verify that the connector on the control board side fits securely and is keyed correctly; forced insertion can damage the pins. Check that the insulation is rated for the combustion head area, as temperatures there can be high.

Signs of failure

A broken, shorted, or high-resistance cable causes the control to fail to detect flame, resulting in lockout. Insulation brittleness or melting near the electrode is a common failure mode that produces intermittent flame loss. Poor contact at either connector can mimic almost any flame detection fault, so always check the cable as a standard step during lockout troubleshooting.

All specifications

Conductor cross-section0.75-1.5
Insulation temperature classF or H
Connector includedYes
Soldering requiredNo
Flame detector typeIonisation
Voltage typeRectified voltage

Part numbers

SKU3008490
Additional article916.298.001

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
105.30 EUR 1