excl. VAT · import VAT and duties on delivery
· shipping calculated at checkout
Delivery to 97 countries
Original manufacturer part
Dispatch within 24 h for stocked items
Description
The Anstoss DCP 2/24 07000410 is an ignition transformer used in burners and boilers. It steps up the mains voltage to a high level to produce a spark across the ignition electrode gap. The transformer is energized only during the ignition period, controlled by the burner control. It features silicone-insulated ignition cables and secondary insulation. The model is DCP 2/24, with SKU 07000410.
Choosing and fitting
When selecting an ignition transformer of this type, ensure the primary voltage (commonly 230 V, but also 110 V or 24 V) matches the burner's control circuit. Check the secondary voltage and current requirements, duty cycle, and physical mounting and terminal types. The cable connector pattern must match existing wiring. Verify the electrode gap and insulation condition before installation.
Signs of failure
Typical failures include cracked or hardened ignition cables that leak spark to earth, mimicking a faulty transformer. A weak spark may be due to cable condition rather than the transformer itself. Check the primary supply and electrode gap if ignition issues occur.