188.96 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8.2 kV |
| Poles / outlets | 2 |
| Construction type | high-frequency electronic |
| Ignition voltage | 26–26 kV |
| Housing type | compact |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Nominal current | 21 mA |
| Electromagnetic interference protection | built-in EMC filter |
| Catalogue article numbers | 15930070, 4111.833, 246.820.035 |
| Ingress protection | IP00 |
| Number of contacts | 2 |
| Peak current (mA) | 62 mA |
| Rated current (mA) | 21 mA |
| Recommended spark distance | 3–5 mm |
| Mounting feature | various mounting and connection systems |
| Built-in filter | built-in EMC filter |
| Output voltage frequency | 10–12 kHz |
| Operating mode | continuous |
| Single electrode operation | possible |
| Core material | ferritic |
| Certification | complies with directive 2004/108/ec |
| Fuel | gas, liquid fuel |
| Application | domestic, commercial and industrial |
| Cycle type | continuous |
| Safety feature | built-in short circuit protection |
| Technology | high-frequency electronic |
| Operating principle | high-frequency electronic step-up transformer |
| Input voltage range | 230 V 50/60 Hz |
| Includes ignition cable | yes |
| External filter not required | yes |
| Secondary current | 21 mA |
| Duty cycle | 100% |
| Net weight | 0.25 kg |
| Power consumption | 19 W |
| Frequency | 50–60 Hz |
Lowest price in the 30 days before the price drop
30.48EUR
in stock · 10excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a high-frequency electronic ignition transformer for gas and liquid fuel burners. It operates from a 230 V 50–60 Hz supply and produces a secondary voltage of 8.2 kV at a rated current of 21 mA. The transformer provides an ignition voltage of 26–26 kV and has a duty cycle of 100%, making it suitable for continuous operation. It incorporates a ferritic-core step-up transformer, a built-in EMC filter, and short-circuit protection, and complies with directive 2004/108/EC. The compact housing supports either single or two-electrode operation and is delivered with an ignition cable up to 1.5 m long. It is intended for domestic, commercial, and industrial burner applications.
Further details
| Interchangeability | can replace most transformers from other manufacturers; dimensions correspond to TC and TD series from Brahma |
|---|---|
| Output Type | single or two-pin high voltage output |
Choosing and fitting
To choose a replacement ignition transformer of this type, compare the mounting dimensions, fixing positions, and the high-voltage connector system against the original unit. These transformers are available with single or two-pin high-voltage outputs, so confirm which configuration the burner requires. The compact housing is often a direct fit for burners that used older TC or TD series transformers from the same manufacturer, but always check the physical fit. Also verify that the supply voltage and frequency match the equipment, and that the ignition cable length does not exceed the transformer's rated maximum (typically 1.5 m).
Fits equipment
Master 4111.833Master BV70Master BV110Master BV170Master BV290Master B230Master B360
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8.2 kV |
| Poles / outlets | 2 |
| Construction type | high-frequency electronic |
| Ignition voltage | 26–26 kV |
| Housing type | compact |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Nominal current | 21 mA |
| Electromagnetic interference protection | built-in EMC filter |
| Catalogue article numbers | 15930070, 4111.833, 246.820.035 |
| Ingress protection | IP00 |
| Number of contacts | 2 |
| Peak current (mA) | 62 mA |
| Rated current (mA) | 21 mA |
| Recommended spark distance | 3–5 mm |
| Mounting feature | various mounting and connection systems |
| Built-in filter | built-in EMC filter |
| Output voltage frequency | 10–12 kHz |
| Operating mode | continuous |
| Single electrode operation | possible |
| Core material | ferritic |
| Certification | complies with directive 2004/108/ec |
| Fuel | gas, liquid fuel |
| Application | domestic, commercial and industrial |
| Cycle type | continuous |
| Safety feature | built-in short circuit protection |
| Technology | high-frequency electronic |
| Operating principle | high-frequency electronic step-up transformer |
| Input voltage range | 230 V 50/60 Hz |
| Includes ignition cable | yes |
| External filter not required | yes |
| Secondary current | 21 mA |
| Duty cycle | 100% |
| Net weight | 0.25 kg |
| Power consumption | 19 W |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 15930070 |
|---|---|
| Additional article | 246.820.035 |
| Model | TCD2FS |
Similar parts
156.00 EURexcl. VAT · import VAT and duties on delivery
86.65 EURexcl. VAT · import VAT and duties on delivery
336.12 EURexcl. VAT · import VAT and duties on delivery
54.00 EURexcl. VAT · import VAT and duties on delivery