Cofi Ignition transformer TRK2-40HK

SKU TRK2-40HK Brand Cofi
Cofi logo — Cofi spare parts for burners and boilers Brand Cofi
Buy Cofi Ignition transformer TRK2-40HK

Key specifications

Supply voltage220–240 V
Length170 mm
Width90 mm
Height55 mm
Manufacturer codeTRK2-40HK
Working withburner control and ignition electrode
Ignition cable insulationsilicone-insulated
Net weight0.33 kg
Gross weight0.37 kg
Frequency50–60 Hz
all specifications (10) ↓

48.52EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi Ignition transformer TRK2-40HK is a compact high-voltage device used to generate a spark in automatic ignition systems for gas and liquid fuel burners. It operates with a supply voltage of 220–240 V and a frequency of 50–60 Hz. The transformer measures 170 mm in length, 90 mm in width, and 55 mm in height, with a net weight of 0.33 kg and a gross weight of 0.37 kg. It is designed to work with burner control and an ignition electrode, and the ignition cable is silicone-insulated. The article number is 309.820.039, and the manufacturer code is TRK2-40HK.

Further details

Advantagescompact housing, stable spark formation, reliable burner ignition, original Cofi product, long service life
Application scopegas burners, diesel burners, combination burners, boiler equipment, heat generators, automatic ignition systems
Energizationenergised only during the ignition period of the burner sequence
Replacement considerationsverify mounting arrangement and terminal configuration against existing installation
Troubleshootinginspect the cable before replacing the transformer

Choosing and fitting

Parts of this type are selected by matching the primary voltage, secondary voltage and current, duty cycle, and physical mounting and terminal configuration to the existing installation. The cable connector pattern must match the existing ignition cable, and the mounting arrangement must align with the burner's design. Before ordering, verify the supply voltage and frequency against the burner control specifications, and ensure the transformer's dimensions fit the available space. The ignition cable should be inspected for hardening or cracks, as a damaged cable can cause spark leakage and mimic a faulty transformer.

Signs of failure

When items of this kind fail, the burner may not ignite or may experience intermittent ignition. Common failure modes include internal short circuits, open windings, or insulation breakdown, which can result in no spark or a weak spark. The equipment may show a lockout condition on the burner control, or the ignition electrode may not produce a visible spark. Check the ignition cable for damage, as a hardened or cracked cable can leak the spark to earth and imitate a faulty transformer. Also, verify that the supply voltage is present and within the specified range.

All specifications

Supply voltage220–240 V
Length170 mm
Width90 mm
Height55 mm
Manufacturer codeTRK2-40HK
Working withburner control and ignition electrode
Ignition cable insulationsilicone-insulated
Net weight0.33 kg
Gross weight0.37 kg
Frequency50–60 Hz

Part numbers

SKUTRK2-40HK
Additional article309.820.039

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
48.52 EUR 1