33.00 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Current | 0.9 A |
| Manufacturer code | TRS818PC |
| Operating principle | step-up transformer |
| Working with | ignition electrode and burner control |
| Ignition cable insulation | silicone-insulated |
| Frequency | 50 Hz |
86.40EUR
in stock · 5excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi TRS818PC is a single-pole ignition transformer designed for automatic ignition systems in gas and liquid fuel burners. It operates with a supply voltage of 230 V at 50 Hz, drawing 0.9 A, and provides a secondary voltage of 8 kV. This step-up transformer works with an ignition electrode and burner control to generate a stable spark for burner startup. The transformer is energized only during the ignition phase, as commanded by the burner control, and connects between the control and the electrode via a silicone-insulated high-voltage cable.
Further details
| Advantages | stable high-voltage spark formation, reliable burner startup, suitable for gas and liquid fuel burners, compact design, original Cofi product, long service life |
|---|---|
| Application scope | gas burners, liquid fuel burners, industrial burner devices, boiler equipment, heat generators, automatic ignition systems |
| Cable condition check | inspect cable and electrode insulator before condemning transformer |
| Energization | energised only during the ignition phase |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify the primary voltage (commonly 230 V, but 110 V and 24 V variants exist), secondary voltage, current rating, duty cycle, physical mounting arrangement, terminal type, and connector pattern on the high-tension cable. Ensure the transformer's specifications match the burner control and electrode requirements. The transformer is typically mounted on a bracket or base plate, and the high-voltage cable must be routed to the electrode without sharp bends or contact with hot surfaces.
Signs of failure
Common failure modes include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark. Symptoms may include intermittent ignition, failure to ignite, or burner lockout. Check the high-voltage cable for hardening or cracks, as a damaged cable can leak spark to ground, mimicking a faulty transformer. Also inspect the electrode insulator for cracks or carbon tracking before condemning the transformer.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Current | 0.9 A |
| Manufacturer code | TRS818PC |
| Operating principle | step-up transformer |
| Working with | ignition electrode and burner control |
| Ignition cable insulation | silicone-insulated |
| Frequency | 50 Hz |
Part numbers
| SKU | TRS818PC |
|---|---|
| Additional article | 309.820.042 |
Similar parts
244.62 EURexcl. VAT · import VAT and duties on delivery
73.86 EURexcl. VAT · import VAT and duties on delivery
50.88 EURexcl. VAT · import VAT and duties on delivery
93.24 EURexcl. VAT · import VAT and duties on delivery
147.06 EURexcl. VAT · import VAT and duties on delivery
95.82 EURexcl. VAT · import VAT and duties on delivery
89.70 EURexcl. VAT · import VAT and duties on delivery