145.68 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Resistant to soot | yes |
|---|---|
| Installation boilers | DTG 350 Nez/Diematic |
| Flame proving effect | proves main flame indirectly |
| Flame signal | conducts small rectified current |
| Safety time | within safety time |
| Control lockout | locks out if signal lost |
93.06EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The De Dietrich 83457007 is an ionisation sensor, categorized under ionization & ignition electrodes. It is designed to prove the presence of a flame during the burner safety sequence by conducting a small rectified current through the flame. If the signal is lost, the burner control locks out within the safety time. This sensor is resistant to soot and is installed in De Dietrich DTG 350 Nez/Diematic boilers. It proves the main flame indirectly, typically via a pilot flame.
Further details
| Failure modes | tip erosion, insulator cracking, soot deposits |
|---|---|
| Genuine replacement importance | must match original dimensions and mounting |
| Incorrect gap effect | may prevent reliable flame detection or cause short |
| Selection criteria | overall length, bend, insulator diameter, gap, mounting flange type |
| Selection parameters | overall length, bend, insulator diameter, gap, mounting flange type |
Choosing and fitting
When selecting an ionisation electrode of this type, critical parameters include the overall length and bend of the rod, insulator diameter, gap between electrode tip and burner earth, and mounting flange type. The exact shape must match the burner design and flame position. For burners with a pilot burner, the electrode is positioned so the pilot flame provides the signal. Ensure the replacement matches original dimensions and mounting arrangement to avoid shorting or unreliable detection.
Signs of failure
Ionisation electrodes are consumable items. Over time, the tip erodes, the ceramic insulator may crack from thermal shock, and soot deposits can insulate the electrode, weakening the flame signal. These failures typically result in nuisance lockouts or delayed ignition. Check for erosion, cracks, and soot buildup on the electrode.
Fits equipment
De Dietrich DTG 350 NEZ/Diematic
All specifications
| Resistant to soot | yes |
|---|---|
| Installation boilers | DTG 350 Nez/Diematic |
| Flame proving effect | proves main flame indirectly |
| Flame signal | conducts small rectified current |
| Safety time | within safety time |
| Control lockout | locks out if signal lost |
Part numbers
| SKU | 83457007 |
|---|---|
| Additional article | 336.946.067 |
Similar parts
37.01 EURexcl. VAT · import VAT and duties on delivery
98.28 EURexcl. VAT · import VAT and duties on delivery
36.90 EURexcl. VAT · import VAT and duties on delivery
94.80 EURexcl. VAT · import VAT and duties on delivery
43.92 EURexcl. VAT · import VAT and duties on delivery
132.00 EURexcl. VAT · import VAT and duties on delivery