Kromschroder Automatic burner control unit IFD258-5/1W 84621630
Brand Kromschroder
Key specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionization or UV |
| Protection class (IP) | IP54 |
| Ambient temperature | -20–60 °C |
| Weight | 682 g |
| Fuel | Gas |
| Firing stages | modulating or stage-controlled |
| Application | directly ignited industrial gas burners |
| Safety standard | EN 60730 |
| Air supply | forced draught |
| Service life under maximum load | 250000 |
| Flame detection methods supported | ionization, UV |
| Safety feature | immediate fault lock-out or restart |
| Application type | industrial gas burners |
| Installation position | any |
| Flame monitoring | yes |
| Max. number of operating cycles | 250000 |
| Cable gland | M16 |
| Sensor voltage | 230 |
| Overvoltage category | III |
| Relative humidity | no condensation permitted |
| Reset button operating cycles | 1000 cycles |
| Mains button operating cycles | 1000 cycles |
| Frequent cycling suitability | yes |
| Enclosure standard | IP54 |
| Net weight | 0.682 kg |
916.80EUR
in stock · 3excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder IFD258-5/1W automatic burner control unit (SKU 84621630) is designed for directly ignited industrial gas burners with forced draught. It supports modulating or stage-controlled burners and can be used in multi-burner setups with central pre-purge and monitoring. The unit operates on 230 V supply voltage, has a safety time of 5 seconds, and monitors flame via ionization or UV sensors. It features immediate fault lock-out or restart on flame failure, with a maximum of 250,000 operating cycles. The control box has IP54 protection, weighs 682 g, and operates in ambient temperatures from -20 to 60 °C.
Further details
| Cable gland | M16 |
|---|---|
| Enclosure | IP 54 pursuant to IEC 529 |
| Installation position | any |
| Mains voltage | 230 V AC, 50/60 Hz |
| Power consumption | approx. 9 VA |
| Relative humidity | no condensation permitted |
| Sensor current | > 2 µA |
| Sensor voltage | approx. 230 V AC |
Choosing and fitting
When selecting a replacement burner control unit of this type, ensure the supply voltage, safety time, and flame detection method (ionization or UV) match the existing system. The unit must be compatible with the burner's fuel type and application (directly ignited industrial gas burners). Check the physical dimensions and cable gland size (M16) for proper mounting. The installation position is any, but the ambient temperature and humidity limits must be respected. Verify the overvoltage category and safety standard compliance (EN 60730) for the specific installation.
Signs of failure
Typical failures of this kind of control unit include failure to ignite, flame loss during operation, or immediate lock-out. Symptoms may include the burner not starting, repeated reset cycles, or the unit displaying a fault status. Check the flame sensor (ionization or UV) for contamination or damage, and verify the supply voltage and wiring connections. If the unit locks out frequently, inspect the flame signal strength and ensure the sensor is correctly positioned.
All specifications
| Supply voltage | 230 V |
|---|---|
| Safety time | 5 s |
| Flame detector type | ionization or UV |
| Protection class (IP) | IP54 |
| Ambient temperature | -20–60 °C |
| Weight | 682 g |
| Fuel | Gas |
| Firing stages | modulating or stage-controlled |
| Application | directly ignited industrial gas burners |
| Safety standard | EN 60730 |
| Air supply | forced draught |
| Service life under maximum load | 250000 |
| Flame detection methods supported | ionization, UV |
| Safety feature | immediate fault lock-out or restart |
| Application type | industrial gas burners |
| Installation position | any |
| Flame monitoring | yes |
| Max. number of operating cycles | 250000 |
| Cable gland | M16 |
| Sensor voltage | 230 |
| Overvoltage category | III |
| Relative humidity | no condensation permitted |
| Reset button operating cycles | 1000 cycles |
| Mains button operating cycles | 1000 cycles |
| Frequent cycling suitability | yes |
| Enclosure standard | IP54 |
| Net weight | 0.682 kg |
Part numbers
| SKU | 84621630 |
|---|---|
| Additional article | 624.103.025 |
| Model | IFD258-5/1W |
Similar parts
1287.60 EURexcl. VAT · import VAT and duties on delivery
2661.60 EURexcl. VAT · import VAT and duties on delivery
3135.60 EURexcl. VAT · import VAT and duties on delivery
2661.60 EURexcl. VAT · import VAT and duties on delivery
2591.40 EURexcl. VAT · import VAT and duties on delivery
2406.00 EURexcl. VAT · import VAT and duties on delivery
2661.60 EURexcl. VAT · import VAT and duties on delivery