Honeywell UV cell UVZ780 18813

SKU 18813 Model UVZ780 Brand Honeywell
Honeywell logo — Honeywell spare parts for burners and boilers Brand Honeywell
Buy Honeywell UV cell UVZ780 18813

Key specifications

Detection principleUV cell
Detection principleUV
Operating principleultraviolet radiation sensing
Fuelgas and oil
Device typeflame sensor
all specifications (5) ↓

811.92EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Honeywell UVZ780 is a flame sensor of the UV cell type for gas and oil burners, operating on the ultraviolet radiation sensing principle. It has article numbers 18813 and 852.211.002 and is designed for direct line-of-sight mounting where the flame is luminous. When combustion occurs, the sensor detects UV radiation and sends a signal to the burner control; loss of signal triggers a safety lockout.

Further details

Application Typeoil and industrial burners with luminous flame
Line of sightdirect line of sight to the flame required
Material qualityhigh-quality materials resistant to high temperatures and aggressive environments
Output Signalsignal to burner control (flame safeguard)
Purposeautomatic monitoring of flame presence in burners and boilers
Safety Functionfuel supply shutoff on flame loss
Typical Failure Modescontaminated viewing window; aged cell producing weakened signal; broken sheath

Choosing and fitting

UV-cell flame sensors are selected by detection principle, spectral range, response time, cable length and connector, and mounting sleeve. When replacing such a sensor, match the original in cable length and connector type, and confirm the mounting sleeve fits the burner's sight port. Position the cell for a direct line of sight to the flame, not to hot refractory or reflected radiation. The burner control must be UV-compatible; no adjustments to the control settings are needed for the sensor itself.

Signs of failure

Typical failures of UV-cell sensors include a contaminated viewing window, an aged cell producing a weakened signal, or a broken sheath. When the sensor fails, the burner control receives no valid UV signal and goes into lockout, shutting down the burner. Check the viewing window for dirt or soot, and verify the sensor's response with the burner control in test mode.

All specifications

Detection principleUV cell
Detection principleUV
Operating principleultraviolet radiation sensing
Fuelgas and oil
Device typeflame sensor

Part numbers

SKU18813
Additional article852.211.002
ModelUVZ780

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
811.92 EUR 1