720.00 EURexcl. VAT · import VAT and duties on delivery
Kromschroder Flame sensor UVS10D0P2 84315209
Brand Kromschroder
Key specifications
| Detection principle | UV |
|---|---|
| Distance between UV sensor and flame | 300–400 mm |
| Ambient temperature | -40–80 °C |
| Weight | 360 g |
| Application | flame sensor for gas burners |
| Material | aluminum housing |
| Purpose | flame monitoring |
| Sensing element | UV tube |
| Installation position | aimed at the flame |
| Operating principle | UV radiation detection |
| Application - Gas burners | yes |
| Electrical connection | 4-pin plug with socket |
| Ingress protection | IP65 |
| Service life | approx. 10,000 operating hours |
| Cable gland diameter | 7–13 mm |
| Connection thread | RP 1/2 internal thread |
| UV tube type | P578 |
| Heat guard | integrated heat guard |
| Housing material | aluminum |
| Lens type | quartz glass |
| Sensor type | UV sensor |
| Application boilers | gas burners |
| Enclosure rating | IP65 |
| Clamping range of the connection terminals | with connection terminals |
| Alignment requirement | aligned on first flame third |
| Cooling air requirement | supply cooling air |
680.40EUR
in stock · 2excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder UVS10D0P2 is a UV flame sensor designed for flame monitoring in gas burners. It operates by detecting UV radiation from the flame using a P578 UV tube, with a spectral range of 190–270 nm and maximum sensitivity at 210 nm. The sensor features an aluminum housing with an integrated heat guard and quartz glass lens, and is rated IP65 for ingress protection. It has a 4-pin plug with socket, a connection thread of RP 1/2 internal, and a cable gland for diameters of 7–13 mm. The recommended distance between the sensor and flame is 300–400 mm, and it operates in ambient temperatures from -40 to 80 °C. The sensor weighs 360 g and has a service life of approximately 10,000 operating hours.
Further details
| Compatible Burner Controls | Elster Kromschroder IFS, IFD, PFS, PFD, IFW, PFF, BCU, PFU |
|---|---|
| Compatible Control Type | Elster Kromschroder automatic burner control units IFS, IFD, PFS, PFD, flame detectors IFW or PFF, burner control units BCU or PFU |
| Compatible control units | IFS, IFD, PFS, PFD, IFW, PFF, BCU, PFU |
| Enclosure | IP 65 |
| Max cable length | in accordance with burner control specifications |
| Min. DC signal | 1 μA |
| Protection from direct sunlight | do not expose to direct sunlight |
| Protection from other UV sources | must be protected from other UV sources |
| UV tube | P578, spectral range: 190–270 nm, max. sensitivity: 210 nm ± 10 nm |
Choosing and fitting
When selecting a UV flame sensor of this type, ensure compatibility with the burner control unit (e.g., Elster Kromschroder IFS, IFD, PFS, PFD, IFW, PFF, BCU, PFU) and that the connection thread (RP 1/2 internal) matches the viewing tube. The sensor must be aligned on the first flame third, where UV radiation is highest, and positioned at a distance of 300–400 mm from the flame. The cable gland must accommodate the cable diameter (7–13 mm), and the electrical connection (4-pin plug with socket) must match the control unit's wiring. Cooling air must be supplied to protect the sensor from high temperatures and contamination.
Signs of failure
Common failure modes for UV flame sensors include degradation of the UV tube, leading to reduced sensitivity or false flame loss signals. Symptoms may include burner lockouts, intermittent flame detection, or failure to detect the flame. Check the sensor's viewing window for dirt or condensation, verify the alignment and distance to the flame, and test the UV tube's output (minimum DC signal 1 µA) to diagnose issues.
Fits equipment
Rp 1/2 internal thread
All specifications
| Detection principle | UV |
|---|---|
| Distance between UV sensor and flame | 300–400 mm |
| Ambient temperature | -40–80 °C |
| Weight | 360 g |
| Application | flame sensor for gas burners |
| Material | aluminum housing |
| Purpose | flame monitoring |
| Sensing element | UV tube |
| Installation position | aimed at the flame |
| Operating principle | UV radiation detection |
| Application - Gas burners | yes |
| Electrical connection | 4-pin plug with socket |
| Ingress protection | IP65 |
| Service life | approx. 10,000 operating hours |
| Cable gland diameter | 7–13 mm |
| Connection thread | RP 1/2 internal thread |
| UV tube type | P578 |
| Heat guard | integrated heat guard |
| Housing material | aluminum |
| Lens type | quartz glass |
| Sensor type | UV sensor |
| Application boilers | gas burners |
| Enclosure rating | IP65 |
| Clamping range of the connection terminals | with connection terminals |
| Alignment requirement | aligned on first flame third |
| Cooling air requirement | supply cooling air |
Part numbers
| SKU | 84315209 |
|---|---|
| Additional article | 624.208.023 |
| Model | UVS10D0P2 |
Similar parts
465.00 EURexcl. VAT · import VAT and duties on delivery
2001.60 EURexcl. VAT · import VAT and duties on delivery
1698.60 EURexcl. VAT · import VAT and duties on delivery
169.79 EURexcl. VAT · import VAT and duties on delivery
539.40 EURexcl. VAT · import VAT and duties on delivery
1962.60 EURexcl. VAT · import VAT and duties on delivery
307.20 EURexcl. VAT · import VAT and duties on delivery