188.96 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | high-frequency electronic generator |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Peak current (mA) | 45 mA |
| Output voltage frequency | 6–10 kHz |
| Ingress protection | ip00 |
| Number of contacts | 1 |
| Core material | ferritic core |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| Protection against temperature fluctuations | special compound |
| High efficiency | high efficiency and ignition power |
| Compact design | compact dimensions |
| Light weight | low weight |
| High-frequency generator | high-frequency electronic generator |
| Mounting and connecting systems | various mounting and connecting systems |
| Protection class (IP) | ip00 |
| Protection | ip00 |
| Output voltage max | 15 kV |
| Peak voltage | 15 kV |
| Secondary current | 45 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | 25 W |
| Frequency | 50–60 Hz |
Lowest price in the 30 days before the price drop
44.64EUR
in stock · 40excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TC1LVCA ignition transformer (SKU 15911000) is a high-frequency electronic generator with a ferritic core, designed for gas and liquid fuel burners. It operates on a supply voltage of 220–240 V at 50–60 Hz, consuming 25 W. The transformer delivers a secondary voltage of 15 kV with a secondary current of 45 mA, and an output voltage frequency of 6–10 kHz. It features a single pole, built-in short circuit protection, and a varistor for surge protection. The unit weighs 0.42 kg and has an ingress protection rating of IP00.
Further details
| Application Scope | gas burners, light and heavy liquid fuel burners |
|---|---|
| Thermal Compound | special compound with high thermal conductivity and special expansion coefficient |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and power consumption match the burner's electrical specifications. Verify the secondary voltage and current requirements of the ignition electrode, as well as the maximum ignition cable length (1.5 m) and standard power cable length (560 mm). The recommended spark distance is 3–5 mm. Mounting and connecting systems vary, so confirm the physical dimensions and contact configuration (number of poles) fit the burner's design. The duty cycle (50%) must be compatible with the burner's operational cycle.
Signs of failure
Typical failures of ignition transformers include internal short circuits, open circuits, or breakdown of insulation, often due to moisture or overheating. Symptoms on the equipment include weak or no spark at the electrode, intermittent ignition, or burner lockout. Check the secondary voltage and current output with appropriate test equipment, inspect the ignition cable for damage, and verify the spark gap is within the recommended range. Also, ensure the supply voltage is stable and within specifications, as surges can damage the internal varistor.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | high-frequency electronic generator |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Peak current (mA) | 45 mA |
| Output voltage frequency | 6–10 kHz |
| Ingress protection | ip00 |
| Number of contacts | 1 |
| Core material | ferritic core |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| Protection against temperature fluctuations | special compound |
| High efficiency | high efficiency and ignition power |
| Compact design | compact dimensions |
| Light weight | low weight |
| High-frequency generator | high-frequency electronic generator |
| Mounting and connecting systems | various mounting and connecting systems |
| Protection class (IP) | ip00 |
| Protection | ip00 |
| Output voltage max | 15 kV |
| Peak voltage | 15 kV |
| Secondary current | 45 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | 25 W |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 15911000 |
|---|---|
| Additional article | 246.820.059 |
| Model | TC1LVCA |
Similar parts
156.00 EURexcl. VAT · import VAT and duties on delivery
86.65 EURexcl. VAT · import VAT and duties on delivery
336.12 EURexcl. VAT · import VAT and duties on delivery