Key specifications

Supply voltage110-120 V 50/60 Hz
Secondary voltage15 kV
Poles / outlets1
Maximum length of ignition cable with integrated electronic ignition1.5 m
Peak current (mA)45 mA
Recommended spark distance3–5 mm
Standard power cable length560 mm
Output voltage frequency6–10 kHz
Ingress protectionIP00
Number of contacts1
Core materialferritic core
EMC filter standarddirective 2004/108/ec
Complies with directive2004/108/ec
Low voltage directive73/23/eec
Short-circuit protectionbuilt-in
High efficiencyhigh efficiency and ignition power
Mounting and connecting systemsvarious mounting and connecting systems
Built-in filterintegrated emc filter
Secondary current45 mA
Duty cycle100%
Net weight0.42 kg
Power consumptionlow power consumption
Frequency50–60 Hz
all specifications (23) ↓
51.00 EUR

Lowest price in the 30 days before the price drop

43.50EUR

in stock · 2

excl. VAT · import VAT and duties on delivery · shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma TC1LVCA ignition transformer (SKU 15911002) is a high-frequency electronic device with a ferritic core, designed to generate ignition sparks for gas and liquid fuel burners. It operates on a supply voltage of 110-120 V at 50/60 Hz, producing a secondary voltage of 15 kV with a secondary current of 45 mA. The transformer features a 100% duty cycle, a single contact, and an integrated EMC filter, complying with directive 2004/108/ec. It has a net weight of 0.42 kg, a recommended spark distance of 3-5 mm, and a maximum ignition cable length of 1.5 m. The output voltage frequency ranges from 6 to 10 kHz, and the standard power cable length is 560 mm. The unit includes built-in short circuit protection and is rated IP00.

Further details

Application scopegas burners, as well as burners for light and heavy types of liquid fuels in domestic, commercial and industrial installations
External filter not requiredno additional external filters are required
Operating principlebased on a high-frequency electronic generator
Overload protectionspecial composition with high thermal conductivity and a special expansion coefficient
Protection against temperature fluctuationsspecial composition with high thermal conductivity and a special expansion coefficient
Single or double contactsingle or double-pin high voltage output
Standardsen 61558-1:1997 + a1:1998 +a11:2003 and en 61558-2-3:2000
Thermal compoundtreated with a special composition with high thermal conductivity and a special expansion coefficient
Varistor protectionbuilt-in varistor protects against power surges

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage and frequency match the burner's electrical system. Verify the secondary voltage and current requirements of the ignition electrode, as well as the spark distance and cable length limits. The transformer must have the correct number of contacts and mounting configuration to fit the burner's connection system. Check the duty cycle to ensure it can handle the burner's operational cycle, and confirm that the EMC filter and compliance standards meet local regulations.

Signs of failure

Common failures in ignition transformers include internal short circuits, open circuits in the secondary winding, or breakdown of insulation leading to arcing. Symptoms may include weak or no spark, intermittent ignition, or visible damage to the transformer casing. Check for continuity in the primary and secondary windings, inspect for signs of overheating or burn marks, and verify that the spark gap is within the recommended range. If the transformer fails, the burner may not ignite or may shut down due to flame detection failure.

All specifications

Supply voltage110-120 V 50/60 Hz
Secondary voltage15 kV
Poles / outlets1
Maximum length of ignition cable with integrated electronic ignition1.5 m
Peak current (mA)45 mA
Recommended spark distance3–5 mm
Standard power cable length560 mm
Output voltage frequency6–10 kHz
Ingress protectionIP00
Number of contacts1
Core materialferritic core
EMC filter standarddirective 2004/108/ec
Complies with directive2004/108/ec
Low voltage directive73/23/eec
Short-circuit protectionbuilt-in
High efficiencyhigh efficiency and ignition power
Mounting and connecting systemsvarious mounting and connecting systems
Built-in filterintegrated emc filter
Secondary current45 mA
Duty cycle100%
Net weight0.42 kg
Power consumptionlow power consumption
Frequency50–60 Hz

Part numbers

SKU15911002
Additional article246.820.017
ModelTC1LVCA

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
43.50 EUR 51.00 EUR 1