The Brahma Ignition transformer TC2LTCAF (SKU 15910460) is a component used to generate the high-voltage spark that ignites fuel in gas or oil burners. It steps up the mains supply voltage to a level that produces a spark across the ignition electrode gap. This transformer operates only during the ignition phase of the burner sequence, under command from the burner control. It is designed for precise control of gas burner valves, providing opening and closing when voltage is applied, with high heat resistance and durable insulation. The model TC2LTCAF is part of the Brahma brand and falls under the category of ignition transformers.

Choosing and fitting

When selecting a replacement ignition transformer of this type, key parameters to match include secondary voltage and current, primary voltage, duty cycle, and physical mounting form. The terminal type and connector pattern for the ignition cable must also match the existing assembly. Check that the primary voltage corresponds to the supply available on the burner (230 V is common, but 110 V and 24 V versions exist). The ignition cable should be silicone-insulated to withstand high voltage and heat.

Signs of failure

Typical failures of ignition transformers include internal short circuits or open windings, leading to no spark or weak spark. A hardened or cracked ignition cable can leak spark to ground, which may mimic a faulty transformer. Symptoms on the equipment include failure to ignite, intermittent ignition, or burner lockout. Check the transformer's output voltage and the condition of the ignition cable before replacing the transformer.

All specifications

Operating phaseignition phase

Part numbers

SKU15910460
Additional article246.820.129
ModelTC2LTCAF

Similar parts

Request an invoice

We issue the invoice for payment by bank transfer and send it by e-mail. Invoices are issued to companies; the EU VAT number is optional.

Delivery address

Drag the pin to the exact spot — it helps the courier find you.

Delivery

Enter the country, postcode and city to see the delivery options.

Invoice {number} has been sent to {email}. Delivery is not included in this invoice: we will confirm its cost by e-mail and send the invoice again with delivery. The invoice is also in your account under Invoices — sign in with this e-mail address. Open the invoice (PDF) Order page Close The request did not go through. Please try again. That’s all we have in stock.
52.56 EUR 58.20 EUR 1