188.96 EURexcl. VAT · import VAT and duties on delivery
Key specifications
| Secondary voltage | 15 kV |
|---|---|
| Poles / outlets | 1 |
| Length | 45 mm |
| Built-in filter | equipped with an electromagnetic filter |
| Ingress protection | IP00 |
| Recommended spark distance | 2–4 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1 m |
| Installation position | any position |
| Duty cycle | 100% |
| Net weight | 0.055 kg |
Lowest price in the 30 days before the price drop
34.38EUR
in stock · 4excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer TR2/A 15909104 is a single-pole ignition transformer with a secondary voltage of 15 kV and a 100% duty cycle. It is equipped with an electromagnetic filter to reduce electromagnetic interference. The transformer has an ingress protection rating of IP00, a net weight of 0.055 kg, and a length of 45 mm. It is designed for use in atmospheric gas burners and can be installed in any position. The recommended spark distance is 2–4 mm, and the maximum ignition cable length is 1 m.
Further details
| Application scope | used in atmospheric gas burners installed in wall-mounted boilers, water heaters, air heaters, convectors, floor boilers and other similar devices |
|---|---|
| Cable routing | do not place high-voltage cables next to others, providing an appropriate level of protection |
| Compatible components | fc modules, cm controllers, fr and dmr, dtmr |
| Electromagnetic interference reduction | designed to reduce electromagnetic interference generated by the ignition transformer |
| Grounding point | arrange the grounding at one point, preventing the appearance of parasitic currents |
| Grounding requirement | ensure that the device is securely grounded for operation |
| Optional resistors | resistors are installed on the transformer to further reduce the level of interference |
| Patent | Italian patent no. 01289096, issued on 09/25/1998 |
Choosing and fitting
When selecting an ignition transformer of this type, ensure that the secondary voltage, duty cycle, and number of poles match the burner's requirements. The transformer's dimensions and mounting configuration must be compatible with the existing installation. Check the recommended spark distance and maximum ignition cable length to ensure proper operation. The transformer can be installed in any position, but the high-voltage cable should be kept as short as possible and routed away from other wiring to minimize interference.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or breakdown of insulation, leading to weak or no spark. Symptoms may include the burner failing to ignite, intermittent ignition, or the transformer overheating. Check for visible damage, measure the secondary voltage with a suitable probe, and inspect the spark electrode and cable for wear or damage.
All specifications
| Secondary voltage | 15 kV |
|---|---|
| Poles / outlets | 1 |
| Length | 45 mm |
| Built-in filter | equipped with an electromagnetic filter |
| Ingress protection | IP00 |
| Recommended spark distance | 2–4 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1 m |
| Installation position | any position |
| Duty cycle | 100% |
| Net weight | 0.055 kg |
Part numbers
| SKU | 15909104 |
|---|---|
| Additional article | 246.820.025 |
| Model | TR2/A |