Fida Dual-spark transformer TE081S05
SKU TE081S05
Brand Fida
Photos
Key specifications
| Supply voltage | 400 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 2 |
| Ingress protection | IP44 |
| Housing material | sealed plastic housing |
| Transformer type | dual-spark, compact |
| Operation mode | continuous operation (ed 100%) |
| Cable insulation type | silicone-insulated |
| Secondary current | 10 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
| Ambient temperature, max | 35 °C |
146.15 EUR
132.86EUR
in stock · 2
incl. 21% VAT · 109.80 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Fida Dual-spark transformer TE081S05 is a compact ignition transformer designed for continuous operation (ED 100%) in gas and oil burners. It operates with a supply voltage of 400 V at 50 Hz, providing a secondary voltage of 8 kV (2 x 4 kV) and a secondary current of 10 mA. The transformer features a sealed plastic housing with IP44 ingress protection and silicone-insulated cables, suitable for ambient temperatures up to 35 °C. It is a dual-spark type with 2 poles, ensuring ignition in industrial burner applications.
Further details
| Operating phase | energised only during the ignition phase of the burner start sequence, under command from the burner control |
|---|---|
| Replacement considerations | verify that the secondary output, primary voltage, physical size, and terminal layout match the transformer being replaced |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the primary voltage (e.g., 230 V, 400 V), secondary voltage and current, duty cycle, and physical dimensions match the existing unit. The terminal layout and cable connector pattern must also be compatible with the burner's wiring. Ensure the transformer is rated for the required duty cycle to avoid overheating during repeated ignition attempts.
Signs of failure
Common failures of ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. Symptoms may include burner ignition failure, intermittent operation, or lockout. Check the high-voltage cable for hardening or cracks, as these can leak spark to earth and mimic a faulty transformer. Inspect the transformer for signs of overheating or physical damage before replacement.
All specifications
| Supply voltage | 400 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 2 |
| Ingress protection | IP44 |
| Housing material | sealed plastic housing |
| Transformer type | dual-spark, compact |
| Operation mode | continuous operation (ed 100%) |
| Cable insulation type | silicone-insulated |
| Secondary current | 10 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
| Ambient temperature, max | 35 °C |
Part numbers
| SKU | TE081S05 |
|---|---|
| Additional article | 462.820.002 |
| Additional article | 462.820.029 |