Fida Dual-spark transformer TE081S05

SKU TE081S05 Brand Fida

Photos

Key specifications

Supply voltage400 V
Secondary voltage8 kV
Poles / outlets2
Ingress protectionIP44
Housing materialsealed plastic housing
Transformer typedual-spark, compact
Operation modecontinuous operation (ed 100%)
Cable insulation typesilicone-insulated
Secondary current10 mA
Duty cycle100%
Frequency50 Hz
Ambient temperature, max35 °C
all specifications (12) ↓
146.15 EUR
132.86EUR
in stock · 2

incl. 21% VAT · 109.80 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Fida Dual-spark transformer TE081S05 is a compact ignition transformer designed for continuous operation (ED 100%) in gas and oil burners. It operates with a supply voltage of 400 V at 50 Hz, providing a secondary voltage of 8 kV (2 x 4 kV) and a secondary current of 10 mA. The transformer features a sealed plastic housing with IP44 ingress protection and silicone-insulated cables, suitable for ambient temperatures up to 35 °C. It is a dual-spark type with 2 poles, ensuring ignition in industrial burner applications.

Further details

Operating phaseenergised only during the ignition phase of the burner start sequence, under command from the burner control
Replacement considerationsverify that the secondary output, primary voltage, physical size, and terminal layout match the transformer being replaced

Choosing and fitting

When selecting a replacement ignition transformer of this type, verify that the primary voltage (e.g., 230 V, 400 V), secondary voltage and current, duty cycle, and physical dimensions match the existing unit. The terminal layout and cable connector pattern must also be compatible with the burner's wiring. Ensure the transformer is rated for the required duty cycle to avoid overheating during repeated ignition attempts.

Signs of failure

Common failures of ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. Symptoms may include burner ignition failure, intermittent operation, or lockout. Check the high-voltage cable for hardening or cracks, as these can leak spark to earth and mimic a faulty transformer. Inspect the transformer for signs of overheating or physical damage before replacement.

All specifications

Supply voltage400 V
Secondary voltage8 kV
Poles / outlets2
Ingress protectionIP44
Housing materialsealed plastic housing
Transformer typedual-spark, compact
Operation modecontinuous operation (ed 100%)
Cable insulation typesilicone-insulated
Secondary current10 mA
Duty cycle100%
Frequency50 Hz
Ambient temperature, max35 °C

Part numbers

SKUTE081S05
Additional article462.820.002
Additional article462.820.029