excl. VAT · import VAT and duties on delivery
· shipping calculated at checkout
Delivery to 97 countries
Original manufacturer part
Dispatch within 24 h for stocked items
Description
This thermocouple is a flame detection device for atmospheric gas burners. It generates a small millivolt signal when heated by a pilot burner flame, which holds open a safety gas valve. The cable length is 900 mm. The maximum operating temperature is 750 °C at the hot junction and 415 °C at the cold junction.
Further details
Safety feature
holds open a safety gas valve; closes on flame loss
Choosing and fitting
Replacements of this type are selected by thread type, tip style, and cable length; these must match the existing pilot burner and gas valve layout. The tip must seat correctly in the pilot burner bracket, and the retaining nut should tighten without cross-threading. Measure the distance from the pilot burner to the gas valve to confirm the cable reaches.
Signs of failure
These thermocouples commonly fail from a broken sheath or diminished signal output caused by thermal cycling or tip contamination. The equipment may keep the pilot lit but fail to fire the main burner, or the pilot may go out after the reset button is released. Checking the tip for contamination and the sheath for damage can reveal the fault.