Fida Ignition transformer TF082D1

SKU TF082D1 Brand Fida

Photos

Key specifications

Supply voltage230 V
Secondary voltage4 kV
Poles / outlets2
Ignition current20 mA
Design featurescompact size
Fuelgas
Applicationgas boilers and burners
Cable insulation typeP
Operating modecontinuous
Housing typecompact
Electrical connectionplug connector
Mounting featuretwo removable brackets
Housing protectionsealed housing
Operating phaseonly during ignition phase
Rated current (mA)0.12 mA
Output configuration1 high-voltage terminal
Ignition cable insulationsilicone-insulated
Sealed housingsealed housing
Safety standardEuropean safety requirements
Secondary current20 mA
Frequency60 Hz
all specifications (21) ↓
121.62 EUR
110.56EUR
in stock · 10

incl. 21% VAT · 91.37 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Fida Ignition transformer TF082D1 is a compact, sealed-housing component designed for gas boilers and burners. It operates on a 230 V supply at 60 Hz, delivering a secondary voltage of 4 kV and a secondary current of 20 mA. The transformer features a plug connector, two removable brackets for mounting, and a silicone-insulated ignition cable. It is energized only during the ignition phase and meets European safety requirements.

Further details

Advantageshigh reliability, operational safety, durability, compatibility
Benefitsconfirmed quality and originality, fast delivery, support in selecting compatible components, detailed information on compatibility
Energizationenergised only during ignition period, under command from burner control, then de-energised once flame is proved
Flame proofflame proved by ionisation electrode or uv detector, then control de-energises transformer
Functionstep mains voltage up to high voltage for spark
Ignition cable conditionhardened or cracked cable can leak spark to earth
Replacement verificationverify primary voltage, secondary output, mounting footprint, terminal layout
Troubleshootinginspect cable and electrode before replacing transformer
Wiringwired to burner control, energised for set safety time while fuel is admitted

Choosing and fitting

Parts of this type are selected by matching primary voltage, secondary voltage and current, duty cycle, mounting arrangement, terminal type, and ignition cable connector pattern. Verify the mounting footprint and terminal layout against the existing bracket and wiring. Ensure the primary voltage (commonly 230 V, but 110 V and 24 V variants exist) and secondary output match the burner design. Check the condition of the ignition cable and electrode before replacing the transformer.

Signs of failure

Typical failures include cracked or hardened ignition cables that leak spark to earth, mimicking a faulty transformer. Contaminated or eroded electrodes may prevent spark formation even with a healthy transformer. When the transformer fails, the burner may not ignite or may shut down during the ignition sequence. Inspect the cable and electrode first to avoid unnecessary part replacement.

Fits equipment

Fida Compact 8/20CM 20% PLUS

All specifications

Supply voltage230 V
Secondary voltage4 kV
Poles / outlets2
Ignition current20 mA
Design featurescompact size
Fuelgas
Applicationgas boilers and burners
Cable insulation typeP
Operating modecontinuous
Housing typecompact
Electrical connectionplug connector
Mounting featuretwo removable brackets
Housing protectionsealed housing
Operating phaseonly during ignition phase
Rated current (mA)0.12 mA
Output configuration1 high-voltage terminal
Ignition cable insulationsilicone-insulated
Sealed housingsealed housing
Safety standardEuropean safety requirements
Secondary current20 mA
Frequency60 Hz

Part numbers

SKUTF082D1
Additional article462.820.006
Additional article462.820.031