Key specifications
| Connection thread | cylindrical |
|---|---|
| Pressure gauge port | g⅛" |
| Vacuum gauge port | g⅛" |
| Valve function | pressure regulation |
| Bypass plug | installed for two-pipe system, remove |
| Strainer open area | 6 cm² |
| Solenoid valve type | normally open |
| Shut-off function | yes |
| Air venting | automatic |
99.00EUR
in stock · 1excl. VAT · import VAT and duties on delivery · shipping calculated at checkout
- Delivery to 97 countries
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Suntec AS47C 1538-6 is an oil pump with a built-in normally open solenoid valve that provides a shut-off function, ensuring quick stopping and resumption of fuel supply. It features a cylindrical connection thread (ISO 228/1), pressure and vacuum gauge ports of G1/8", and a bypass plug installed for two-pipe systems (remove for one-pipe). The pump has a strainer with an open area of 6 cm² and automatic air venting in two-pipe systems. Its valve function is pressure regulation, and it is designed for use in burners and boilers.
Further details
| Cone gaskets | possibility for variants 5 and 6 |
|---|---|
| Mounting | sleeve or flange, per en 225 |
Choosing and fitting
When selecting a replacement oil pump of this type, ensure the connection thread type (cylindrical or conical) and size match the existing piping, as well as the shaft diameter and mounting configuration (flange or sleeve per EN 225). Verify the bypass plug configuration for the system type (two-pipe or one-pipe) and that the pressure and vacuum gauge port sizes are compatible. Also, check the solenoid valve type (normally open or closed) and the shut-off function requirements to match the burner control system.
Signs of failure
Common failures in oil pumps of this kind include loss of pressure due to a clogged strainer or worn gears, leading to burner ignition issues or unstable flame. A faulty solenoid valve may cause fuel to continue flowing after shutdown, resulting in dripping or flooding. Air ingress can occur if seals fail, causing erratic operation or failure to start. Check the strainer for debris, test the solenoid valve for proper operation, and inspect connections for leaks.
All specifications
| Connection thread | cylindrical |
|---|---|
| Pressure gauge port | g⅛" |
| Vacuum gauge port | g⅛" |
| Valve function | pressure regulation |
| Bypass plug | installed for two-pipe system, remove |
| Strainer open area | 6 cm² |
| Solenoid valve type | normally open |
| Shut-off function | yes |
| Air venting | automatic |
Part numbers
| SKU | 34024206 |
|---|---|
| Additional article | 916.520.218 |
| Model | AS47C 1538-6 |
Fits burners · 8
Baltur BTL 10
Oil · 60.2–118 kW
All parts for this burner →
Baltur BTL 10 H
Oil · 60.2–118 kW
All parts for this burner →
Baltur BTL 3 H
Oil · 16.6–42.7 kW
All parts for this burner →
Baltur BTL 3 L200
Oil · 17.8–42.7 kW
All parts for this burner →
Baltur BTL 4 H
Oil · 26–56 kW
All parts for this burner →
Baltur BTL 4 L200
Oil · 26–56.1 kW
All parts for this burner →
Baltur BTL 6
Oil · 31.9–74.3 kW
All parts for this burner →
Baltur BTL 6 H
Oil · 31.9–74.3 kW
All parts for this burner →
Similar parts
99.00 EURexcl. VAT · import VAT and duties on delivery
88.71 EURexcl. VAT · import VAT and duties on delivery
87.00 EURexcl. VAT · import VAT and duties on delivery
87.00 EURexcl. VAT · import VAT and duties on delivery
467.00 EURexcl. VAT · import VAT and duties on delivery
69.00 EURexcl. VAT · import VAT and duties on delivery