Steinen Oil nozzle 0.75GPH / 60S

SKU 0.75GPH / 60S Brand Steinen

Photos

no photo yet

Key specifications

Flow rate0.75 GPH
Spray angle60 °
Spray patternS
all specifications (3) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items
Specifications

Description

This is a Steinen oil nozzle with a flow rate of 0.75 GPH, a 60 ° spray angle, and an S spray pattern. It is used in oil-fired burners and boilers to atomise fuel oil into a spray for combustion. The 0.75 GPH rating defines the volume of oil delivered per hour at the nozzle's rated pressure. The 60 ° angle sets the width of the spray cone, and the S pattern denotes a solid spray distribution.

Nozzle selection chart

Flow rate kg/h 45°60°80°
0.40 1.27 ST
0.45 1.43 ST
0.50 1.59 ST
0.55 1.75 ST
0.60 1.91 SST
0.65 2.07 S
0.75 2.38 S
0.85 2.70 S
1.00 3.18 HS S
1.10 3.50 S
1.20 3.82 S
1.25 3.97 S
1.35 4.29 S
1.50 4.77 S
1.65 5.25 S
1.75 5.56 S S
2.00 6.36 S S
2.25 7.15 S S
2.50 7.95 S
2.75 8.74 S
3.00 9.54 S
3.50 11.13 S
4.00 12.72 S
4.50 14.31 SS SS
5.00 15.90 SS SS
5.50 17.49 SS SS
6.00 19.08 SS SS SS
6.50 20.67 SS SS
7.00 22.26 SS SS
7.50 23.85 SS SS
8.00 25.44 SS SS
8.50 27.02 SS
9.00 28.61 SS SS SS
10.00 31.79 SS SS SS
11.00 34.97 SS SS
12.00 38.15 SS SS
13.00 41.33 SS SS
14.00 44.51 SS SS
15.00 47.69 SS SS
16.00 50.87 SS SS
17.00 54.05 SS SS
18.00 57.23 SS SS
20.00 63.59 SS SS
22.00 69.95 SS SS
24.00 76.31 SS SS
26.00 82.66 SS SS
28.00 89.02 SS
30.00 95.38 SS

Choosing and fitting

Nozzles of this type are selected by matching the flow rate, spray angle, and spray pattern to the burner manufacturer's specification. The mounting form and thread must also match the nozzle adapter or holder on the burner. Before ordering, compare the existing nozzle's markings and the burner's technical data to the required flow rate, angle, and pattern.

Signs of failure

Nozzles of this kind can clog, wear at the orifice, or develop a distorted spray pattern over time. When this happens, the burner may show poor combustion, smoke, soot deposits, or difficulty sustaining a flame. Check the nozzle for blockage or wear and verify the spray pattern and flow rate against the burner specification.

All specifications

Flow rate0.75 GPH
Spray angle60 °
Spray patternS

Part numbers

SKU0.75GPH / 60S
Additional article908.892.070