Steinen Oil nozzle 1.00GPH / 60H

SKU 1.00GPH / 60H Brand Steinen
Steinen logo — Steinen spare parts for burners and boilers Brand Steinen
Buy Steinen Oil nozzle 1.00GPH / 60H

Key specifications

Flow rate1 GPH
Spray angle60 °
Spray patternH
all specifications (3) ↓

—price on request

Not in stock

shipping calculated at checkout

  • Delivery to 97 countries
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Choose a nozzle by its marks

Nozzles of different brands interchange when the marks match: Flow rate, Spray angle, Spray pattern. Set them as on the old nozzle — below are the ones that fit, with price and stock.

Description

The Steinen Oil nozzle 1.00GPH / 60H is an oil burner nozzle with a flow rate of 1 GPH, a 60 ° spray angle and an H spray pattern. It is used to atomise fuel oil into a spray that the burner ignites. The 1 GPH rating defines the volume of oil passed per hour at the nozzle's rated pressure. The 60 ° angle sets how wide the spray cone opens from the nozzle outlet. The H pattern denotes the distribution of droplets within that cone.

Nozzle selection chart

Flow rate kg/h 45°60°80°
0.40 1.27 ST
0.45 1.43 ST
0.50 1.59 ST
0.55 1.75 ST
0.60 1.91 SST
0.65 2.07 S
0.75 2.38 S
0.85 2.70 S
1.00 3.18 HS S
1.10 3.50 S
1.20 3.82 S
1.25 3.97 S
1.35 4.29 S
1.50 4.77 S
1.65 5.25 S
1.75 5.56 S S
2.00 6.36 S S
2.25 7.15 S S
2.50 7.95 S
2.75 8.74 S
3.00 9.54 S
3.50 11.13 S
4.00 12.72 S
4.50 14.31 SS SS
5.00 15.90 SS SS
5.50 17.49 SS SS
6.00 19.08 SS SS SS
6.50 20.67 SS SS
7.00 22.26 SS SS
7.50 23.85 SS SS
8.00 25.44 SS SS
8.50 27.02 SS
9.00 28.61 SS SS SS
10.00 31.79 SS SS SS
11.00 34.97 SS SS
12.00 38.15 SS SS
13.00 41.33 SS SS
14.00 44.51 SS SS
15.00 47.69 SS SS
16.00 50.87 SS SS
17.00 54.05 SS SS
18.00 57.23 SS SS
20.00 63.59 SS SS
22.00 69.95 SS SS
24.00 76.31 SS SS
26.00 82.66 SS SS
28.00 89.02 SS
30.00 95.38 SS

Choosing and fitting

Nozzles of this type are selected by matching the flow rate, spray angle and spray pattern to the burner's requirements, and by matching the thread and body form to the nozzle holder. Mounting forms differ between manufacturers and burner series, so the seat, thread and overall length must be compared with the old part before ordering. The nozzle is fitted into the holder with the correct seating torque and the electrode gap and position are checked afterwards.

Signs of failure

Nozzles of this kind commonly fail by clogging, wear of the orifice, or a distorted spray pattern. The equipment may then show a weak or uneven flame, delayed ignition, sooting, or a rise in flue gas temperature. Checks include the spray pattern on a test stand, the flow rate against the rated value, and the condition of the strainer and nozzle seat.

All specifications

Flow rate1 GPH
Spray angle60 °
Spray patternH

Part numbers

SKU1.00GPH / 60H

Similar parts

—price on request