Steinen Oil nozzle 15.00GPH / 60SS

SKU 15.00GPH / 60SS Brand Steinen

Photos

no photo yet

Key specifications

Flow rate15 GPH
Spray angle60 °
Spray patternSS
all specifications (3) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items
Specifications

Description

This is a Steinen oil nozzle with a flow rate of 15 GPH, a 60° spray angle, and an SS spray pattern. It is used to atomize fuel oil in a burner, producing a cone-shaped spray for combustion. The 60° angle defines the spread of the spray, while the SS pattern indicates a solid cone. The 15 GPH rating specifies the volume of oil delivered per hour at the rated pressure. It is identified by the SKU 15.00GPH / 60SS.

Nozzle selection chart

Flow rate kg/h 45°60°80°
0.40 1.27 ST
0.45 1.43 ST
0.50 1.59 ST
0.55 1.75 ST
0.60 1.91 SST
0.65 2.07 S
0.75 2.38 S
0.85 2.70 S
1.00 3.18 HS S
1.10 3.50 S
1.20 3.82 S
1.25 3.97 S
1.35 4.29 S
1.50 4.77 S
1.65 5.25 S
1.75 5.56 S S
2.00 6.36 S S
2.25 7.15 S S
2.50 7.95 S
2.75 8.74 S
3.00 9.54 S
3.50 11.13 S
4.00 12.72 S
4.50 14.31 SS SS
5.00 15.90 SS SS
5.50 17.49 SS SS
6.00 19.08 SS SS SS
6.50 20.67 SS SS
7.00 22.26 SS SS
7.50 23.85 SS SS
8.00 25.44 SS SS
8.50 27.02 SS
9.00 28.61 SS SS SS
10.00 31.79 SS SS SS
11.00 34.97 SS SS
12.00 38.15 SS SS
13.00 41.33 SS SS
14.00 44.51 SS SS
15.00 47.69 SS SS
16.00 50.87 SS SS
17.00 54.05 SS SS
18.00 57.23 SS SS
20.00 63.59 SS SS
22.00 69.95 SS SS
24.00 76.31 SS SS
26.00 82.66 SS SS
28.00 89.02 SS
30.00 95.38 SS

Choosing and fitting

Nozzles of this type are selected by matching the flow rate, spray angle, and spray pattern to the burner manufacturer's specification. The mounting form must also match: check the thread size, the length and diameter of the nozzle body, and the sealing method before ordering. Compare the old nozzle's markings and dimensions with the replacement to ensure compatibility.

Signs of failure

Nozzles of this kind can clog, wear at the orifice, or develop a distorted spray pattern over time. When this happens, the burner may show a smoky flame, poor combustion, delayed ignition, or a noticeable drop in heat output. Inspect the nozzle for debris or damage and verify the spray shape and flow rate against the specification.

All specifications

Flow rate15 GPH
Spray angle60 °
Spray patternSS

Part numbers

SKU15.00GPH / 60SS