Danfoss Oil nozzle 0.65GPH,45S 030F4914

SKU 030F4914 Brand Danfoss

Photos

no photo yet

Key specifications

Flow rate0.65 GPH
Spray angle45 °
Spray patternS
all specifications (3) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items
Specifications

Description

The Danfoss 030F4914 is an oil nozzle with a flow rate of 0.65 GPH, a 45 ° spray angle, and an S spray pattern. It is used in oil burners to atomise fuel into a fine spray for combustion. The 0.65 GPH rating defines the volume of oil delivered per hour at the nozzle's rated pressure. The 45 ° angle sets the width of the spray cone, and the S pattern denotes a solid spray shape.

Nozzle selection chart

Flow rate kg/h 30°45°60°80°
0.30 0.95 HS HS
0.35 1.11 S S
0.40 1.27 S HS HS
0.45 1.43 S S HS
0.50 1.59 S S HS HS
0.55 1.75 S HS HS
0.60 1.91 S HS BHS BHS
0.65 2.07 BS BHS BHS
0.75 2.38 S BS BHS BHSSR
0.85 2.70 S BHS BHSSR BHS
1.00 3.18 S BS BHS BHS
1.10 3.50 S HS S
1.20 3.82 S HS S
1.25 3.97 S BS BHS BHS
1.35 4.29 BS BHS BHS
1.50 4.77 S BS BHS BHS
1.65 5.25 S HS HS
1.75 5.56 S S HS S
2.00 6.36 S BS BHS BHS
2.25 7.15 S BS BHS S
2.50 7.95 S BS BHS BS
2.75 8.74 BS BHS HS
3.00 9.54 S BS BHS BHS
3.50 11.13 S S S
3.75 11.92 B B B
4.00 12.72 S S S
4.50 14.31 BS BS BS
5.00 15.90 BS BS BS
5.50 17.49 BS BS BS
6.00 19.08 BS BS BS
6.50 20.67 B B B
7.00 22.26 S
7.50 23.85 B B B
8.00 25.44 S
8.50 27.02 B B B
9.00 28.61 S
10.00 31.79 B B B
11.00 34.97 B B B
12.00 38.15 B B B
13.50 42.92 B B B
15.00 47.69 B B B
17.00 54.05 B B
19.50 62.00 B B
22.00 69.95 B B B
25.00 79.49 B B
28.00 89.02 B B
31.50 100.15 B B B
35.00 111.28 B

Choosing and fitting

Nozzles of this type are selected by matching the flow rate, spray angle, and spray pattern to the burner's requirements. The mounting form and thread must match the nozzle adapter or holder on the burner. Before ordering, compare the existing nozzle's markings and dimensions with the replacement. The pump pressure and filtration should also be checked, as they affect atomisation.

Signs of failure

Nozzles of this kind can clog, wear at the orifice, or develop a distorted spray pattern over time. When this happens, the burner may produce a smoky flame, fail to ignite, or run erratically. A fitter should check for carbon deposits, inspect the spray shape, and verify the flow rate against the burner specification.

All specifications

Flow rate0.65 GPH
Spray angle45 °
Spray patternS

Part numbers

SKU030F4914