Danfoss Oil nozzle 1.00GPH,80H 030H8920

SKU 030H8920 Brand Danfoss

Photos

no photo yet

Key specifications

Flow rate1 GPH
Spray angle80 °
Spray patternH
all specifications (3) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items
Specifications

Description

This is a Danfoss oil nozzle with a flow rate of 1 GPH, a spray angle of 80°, and an H spray pattern. It is used in oil burners to atomise fuel oil into a fine spray for combustion. The 80° angle defines the cone width of the spray, while the H pattern denotes the distribution of fuel within that cone. The 1 GPH rating specifies the volume of oil delivered per hour at the nozzle's rated pressure. It is identified by the SKU 030H8920.

Nozzle selection chart

Flow rate kg/h 30°45°60°80°
0.30 0.95 HS HS
0.35 1.11 S S
0.40 1.27 S HS HS
0.45 1.43 S S HS
0.50 1.59 S S HS HS
0.55 1.75 S HS HS
0.60 1.91 S HS BHS BHS
0.65 2.07 BS BHS BHS
0.75 2.38 S BS BHS BHSSR
0.85 2.70 S BHS BHSSR BHS
1.00 3.18 S BS BHS BHS
1.10 3.50 S HS S
1.20 3.82 S HS S
1.25 3.97 S BS BHS BHS
1.35 4.29 BS BHS BHS
1.50 4.77 S BS BHS BHS
1.65 5.25 S HS HS
1.75 5.56 S S HS S
2.00 6.36 S BS BHS BHS
2.25 7.15 S BS BHS S
2.50 7.95 S BS BHS BS
2.75 8.74 BS BHS HS
3.00 9.54 S BS BHS BHS
3.50 11.13 S S S
3.75 11.92 B B B
4.00 12.72 S S S
4.50 14.31 BS BS BS
5.00 15.90 BS BS BS
5.50 17.49 BS BS BS
6.00 19.08 BS BS BS
6.50 20.67 B B B
7.00 22.26 S
7.50 23.85 B B B
8.00 25.44 S
8.50 27.02 B B B
9.00 28.61 S
10.00 31.79 B B B
11.00 34.97 B B B
12.00 38.15 B B B
13.50 42.92 B B B
15.00 47.69 B B B
17.00 54.05 B B
19.50 62.00 B B
22.00 69.95 B B B
25.00 79.49 B B
28.00 89.02 B B
31.50 100.15 B B B
35.00 111.28 B

Choosing and fitting

Nozzles of this type are selected by matching the flow rate, spray angle, and spray pattern to the burner's requirements, and by confirming the thread and mounting form suit the nozzle holder. The flow rate must correspond to the burner's rated input, the spray angle to the combustion chamber geometry, and the pattern to the air flow arrangement. Before ordering, compare the existing nozzle's markings and its seat and thread with the replacement.

Signs of failure

Nozzles of this kind commonly fail by clogging, wear of the orifice, or a distorted spray pattern. When this happens the burner may produce a poor flame, smoke, soot, or fail to ignite, and the combustion may become unstable. Check the spray pattern, the flow rate, and for blockages or wear at the orifice.

All specifications

Flow rate1 GPH
Spray angle80 °
Spray patternH

Part numbers

SKU030H8920